Vari Lite VL2402 User Manual page 106

Table of Contents

Advertisement

VARI LITE® - VL2402™ W
Error Display
B2M2
Ambr
NoSn
B2M2
Ambr
SAct
BRD1
NO
COMM
BRD2
NO
COMM
LAMP
STRK
FAIL
PAN
ENCR
FAIL
88
L
U
'
ASH
UMINAIRE
SER
Table A-1: VL2402 Troubleshooting Guide (Continued)
Description
Aux Board 2, Motor 2,
Amber,
Sensor Not Found
Aux Board 2, Motor 2,
Amber,
Sensor Always Active
Aux Board 1
Communication Failure
Aux Board 2
Communication Failure
Lamp Strike Failure
Pan Encoder Failure
17-Sept-01
M
S
ANUAL
Possible Cause and Remedy
Amber power not connected, motor
not moving
- Connect Amber power at motor
Amber sensor not connected
- Connect Amber sensor
Amber movement restricted or
impeded
- Remove obstruction
Amber sensor is faulty
- Replace color sensor assembly
Aux Board 2 is faulty
Replace aux board
Amber power not connected, and
amber aligned with sensor
- Connect Amber power at motors
Aux input connector (J5) not
connected to either aux board
- Connect aux input connector (J5)
to either aux board
Jumper/bridge connector (J1)
between aux boards not connected
- Install jumper/bridge connector
(J1) between aux boards
Aux input connector (J5) not
connected to either aux board
- Connect aux input connector (J5)
to either aux board
Jumper/bridge connector (J1)
between aux boards not connected
- Install jumper/bridge connector
(J1) between aux boards
Lamp failed to strike after repeated
attempts
- Replace lamp
Main board pan/tilt connector (J9)
disconnected
- Connect main board pan/tilt
connector (J9)
Pan motor disconnected
- Connect pan motor power
Encoder faulty
Replace pan end-of-travel/encoder
sensor assembly
02. 9671.0 001 C

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents