Vari Lite VL2402 User Manual page 65

Table of Contents

Advertisement

Correct
Trouble
Note: Without any data connected, the normal standby cycle of the Rx LED is 2 sec
on, 2 sec off.
Note: The number of blocks displayed will be less in a luminaire-to-luminaire
download than in a PC-to-luminaire download for the same software version.
8. Once download is complete, luminaire will automatically recalibrate. Once
Verify software version at luminaire:
1. At Menu Display, press [Menu].
2. Press [Up] / [Down] arrows until Fixt (Fixture) appears. Press [Enter].
3. Press [Up] / [Down] arrows until Ver (Version) appears. Press [Enter].
02.9 671.00 01 C
The receiving luminaire's green Rx LED will blink rapidly and its menu will
display number of blocks received (this number will vary depending on
software version being downloaded). This indicates that data is being sent
from luminaire to luminaire. However, if display does not show blocks as
they are received, this indicates that the version being downloaded matches
the one already installed or that the luminaire type does not match.
If the receiving luminaire's green Rx LED does not blink rapidly and its
menu does not display blocks, this indicates that no data is being received.
(Check cable connections, Loopback Connector, etc. and ensure ALL
cabling is the 5-conductor type.)
recalibration is complete, luminaire is ready for operation with its new
software version.
The first half of the version date will be displayed as MM.DD. (month.day):
For example, 07.21. = July 21
Press [Up] / [Down] arrows to display second half of version date.
The second half of the version date will be displayed as YY.TT (year.time):
For example, 00.XX = Year 2000, XX timecode
17-Sept-01
O
: U
PERATION
PDATING
3
S
OFTWARE
47