VARI LITE® - VL2402™ W
CAUTION: Wear cotton gloves or other covering while servicing lamp. Touching
lamp glass with bare fingers will leave oil and may cause the lamp to explode or
reduce lamp life. If required, use alcohol and cotton cloth to thoroughly clean glass
portion of lamp.
4. Remove lamp by pulling straight out of socket.
5. Install new lamp by pressing into socket. Ensure lamp is fully seated in
6. Align guide rods in guide holes and slide backcap into head assembly. Re-
7. If required, reset lamp hour and strike counters as follows. (Refer to
8. Align lamp. Refer to
92
L
U
ASH
UMINAIRE
socket and parallel to guide rods. (Lamp can be damaged when inserted
through reflector if not parallel to guide rods.)
tighten captive knob.
4: Menu System
for more information.)
a. Power up luminaire.
b. At Menu Display, press [Menu].
c. Press [Up] / [Down] arrows until CFG (Configuration) appears. Press
[Enter].
d. Press [Up] / [Down] arrows until LAMP appears. Press [Enter].
e. Press [Up] / [Down] arrows to access RHrs. Press [Enter] to reset lamp
hour and strike counters.
"Align Lamp for Flat Field" on page
17-Sept-01
'
M
SER
S
ANUAL
Chapter
22.
02. 9671.0 001 C