Function Definitions - Vari Lite VL2402 User Manual

Table of Contents

Advertisement

VARI LITE® - VL2402™ W

Function Definitions

Each menu item is listed in the first column by its display abbreviation. The
abbreviations appear in alphabetical order.
Display
Definition
⇓⇓
Display Orientation
⇑⇑
Display Orientation
8
Standard 8-bit
16
Standard 16-bit
10M
10 Minutes
30s
30 Seconds
5M
5 Minutes
Addr
Address
ALL
All Motors
Ambr
Amber
Auto
Auto Detect or
Auto Playback
Blue
Blue
BTim
Beam Time
C ON
On after Calibration Configures arc luminaire so that lamp will strike after calibration procedure is
Cal
Re calibrate
CFG
System
Configuration
CWhl
Color Wheel
CMiX
Color Mixer
CTim
Color Time
Cue
Cue Processing
cXX
Cue Data
cXXX
DMX Channel
DATA
DMX Data
DDir
Display Orientation
Del
Delete Cue
DIFF
Diffusion
Dimm
Dimmer
Dis
Disable
DisP
Display Illumination
DISP
Display Test
62
L
U
'
ASH
UMINAIRE
SER
S
Table 4-3: Menu Function Definitions
Shows upside-down orientation (for hanging luminaires)
Shows upright orientation.
Configures luminaire for operation in standard DMX 8-bit mode.
Configures luminaire for operation in standard DMX 16-bit mode.
Sets Menu Display to automatically shut off after 10 minutes of non-use.
Sets Menu Display to automatically shut off after 30 seconds of non-use.
Sets Menu Display to automatically shut off after 5 minutes of non-use.
Accesses functions for setting luminaire starting address in either Virtuoso
(VIRT) or DMX (DMX) controlled systems.
Tests all internal motors.
Specifies Amber for manual control (Man) or test Amber functions (Test).
Automatically detects required Menu Display orientation when selected (DDir) or
initiates automatic playback of a cue sequence at power-up (CUE).
Specifies Blue for manual control (Man) or tests Blue functions (Test).
Accepts timing value for beam time.
complete.
Re calibrates luminaire.
Accesses functions for setting lamp start up, pan/tilt, and Menu Display
configurations. Also accesses lamp information such as number of strikes, and
hours used, along with their respective reset function.
Specifies Color Wheel for manual control and test.
Tests color mixing mechanism.
Sets color time. This applies to Blue, Amber, Magenta and Color Wheel.
Accesses cue store, modify, delete, and playback commands.
Specifies cue number for display of current data value.
Specifies DMX channel for display of current data value.
Accesses function for displaying DMX data by channel number.
Accesses option to orient Menu display for reading correctly in either hanging or
floor mounting installations.
Deletes cues by number. Cue number deleted is dependent on last cue ID in cue
list since this field is not editable.
Specifies manual control of Diffusion (Man) or tests Diffusion functions (Test).
Specifies dimmer mechanism for manual control (Man) or tests dimmer/strobe
functions (Test).
Disables a function.
Accesses options for Menu Display on and off times.
Tests all 14 segments in the Display.
17-Sept-01
M
ANUAL
Purpose
02. 9671.0 001 C

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents