System Fan; System System - Intel P4308CP4MHEN Quick Installation User's Manual

P4000cp series
Table of Contents

Advertisement

Warning
Read all caution and safety
statements in this document
before performing any of the
instructions. Also see the Intel
®
Server Board and Server Chassis
Safety Information document at:
http://www.intel.com/support/
motherboards/server/sb/cs-010770
.htm
for complete safety information.
Intel is a registered trademark of Intel Corporation or its subsidiaries in the United States and other countries. *Other names and brands may be claimed as the
property of others. Copyright © 2011, Intel Corporation. All rights reserved.
®
Intel
Server System P4000CP Family Product Configuration
Thermal Operation and Configuration Requirements
Five
Intel® Server
To keep the system operating within supported maximum thermal limits, the system must meet the following operating and
Hot Swap
System
System
configuration guidelines:
Fans
(80 x 38 mm)
P4308CP4MHEN
P4308CP4MHGC
P4208CP4MHGC
= Configuration Feature
Thermal Operation and Configuration Requirements
To keep the system operating within supported maximum thermal limits, the system must meet the following operating and configuration
guidelines:
• Ambient in-let temperature cannot exceed 35º C and should not remain at this maximum level for long periods of time. Doing so
may affect long term reliability of the system.
• The CPU-1 processor and CPU heatsink must be installed.
• DIMM Population on CPU-1: Install DIMMs in order; Channels A, B, C, and D. Start with 1st DIMM slot (blue) on each
channel.
• DIMM Population on CPU-2: Install DIMMs in order; Channels E, F, G, and H. Start with 1st DIMM slot (blue) on each
channel.
• All hard drive bays must be populated. Hard drive carriers either can be populated with a hard drive or supplied drive blank.
• The air duct must be installed at all times.
• In single power supply configurations, the second power supply bay must have the supplied filler blank installed at all times.
• The system top-cover must be installed at all times.
Warning
Installation and service
of this product to be
performed only by
qualified service personnel
to avoid risk of injury from
electrical shock or energy
hazard.

System Fan

One
One
Fixed
Fixed
PCI Zone
CPU Zone
Fan
Fan
(120 x 38 mm)
(120 x 38 mm)
ii
Caution
Observe normal ESD
[Electrostatic Discharge]
procedures during system
integration to avoid possible
damage to server board and/or
other components.
Hard Drive
Power Supply
One
8 x 3.5"
8 x 2.5"
Fixed
Hot Swap
Hot Swap
550W
Tools Required
Flat Blade
screwdriver
Phillips*
screwdriver
Anti-static
wrist strap
Intel®
RAID
C600
Two
Hot Swap
Upgrade
750W
Key
RKSATA8
RKSATA8
RKSAS8

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

P4308cp4mhgcP4208cp4mhgc

Table of Contents