Output Signals And Operation Restrictions When A Camcorder; System Is Configured (In Hd Mode Only) - Sony PXW-X320 Operating Instructions Manual

Hide thumbs Also See for PXW-X320:
Table of Contents

Advertisement

Output Signals and Operation Restrictions When a
Camcorder System is Configured (in HD Mode Only)
The table below shows output signals from the camcorder and operation restrictions to the camcorder
when it is connected with a camera adaptor and camera control unit to configure a shooting and recording
system.
When the camcorder is equipped with the CA-FB70/CA-TX70 HD Camera Adaptor, full HD signals
complying with the HD-SDI standard are transferred to the camera adaptor.
Note
When configuring a camcorder system with a camera adaptor and camera control unit, install the optional CBK-CE01 50
Pin Interface and Digital Extender. Set "OPERATION" > "Format" > "HD/SD" to "HD" in the setup menu.
Settings of Rec Format and
System Frequency under
OPERATION >Format in
the setup menu
XAVC-I 1920/59.94i
XAVC-L50 1920/59.94i
XAVC-L35 1920/59.94i
XAVC-L25 1920/59.94i
HD422 1920/59.94i
HQ1920/59.94i
HQ1440/59.94i
SP1440/59.94i
XAVC-I 1920/29.97P
XAVC-L50 1920/29.97P
XAVC-L35 1920/29.97P
HD422 1920/29.97P
HQ1920/29.97P
HQ1440/29.97P
SP1440/23.98P
XAVC-I 1920/23.98P
XAVC-L50 1920/23.98P
XAVC-L35 1920/23.98P
HD422 1920/23.98P
a)
HQ1920/23.98P
b)
HQ1920/23.98P
a)
HQ1440/23.98P
b)
HQ1440/23.98P
SDI outputs to the
camera adaptor
1920×1080/59.94i
1920×1080/29.97PsF
1920×1080/59.94i (2-
3PD)
Output disabled
1920×1080/59.94i (2-
3PD)
Output disabled
1920×1080/59.94i (2-
3PD)
202
System format of the
camera adaptor and
camera control unit
1920×1080/59.94i
Not supported
1920×1080/59.94i
Not supported
1920×1080/59.94i
Operation restrictions to the
camcorder
Genlock
Return video
display
Available
Available
Unavailable
Unavailable
Available
Unavailable
Unavailable
Unavailable
Available
Unavailable