B-4
To make a connection between PCPro and the system:
1.
Select a Connection Type and specify the settings relevant to the
selected type.
TIP
2.
Specify the User Name and Password used to allow the connection.
3.
Alternatively, steps 1~2 can be skipped loading a defined connection
account (refer to
4.
Press the Connect button.
After a successful connection, the connection settings that are used are
set to the File Properties.
2.2.1
Connection Types
PCPro supports four types of connections to a system. Two connection
types are for SV9100 and three apply only to IPK II.
Connection Types for SV9100:
IP
An IP Connection can be made via a LAN or the Internet. The IP
address specified should match the system setting 10-12-01. If
connecting to the ethernet port on the VoIP daughter board, use the
IP address setting in 10-12-09.
Dial-up
An IP Connection via Dial-up can be made via a dial-up connection,
either through ISDN or an analog modem.
NOTE
Outbound IP
Use this connection type if connecting to the system via a outbound
IP connection. The listen port number should match the value of 90-
69-01 on the system. And the IP address of the PC should match the
value of 90-62-02.
Connection Types for IPK II only:
LAN
An IP Connection can be made via the LAN. The IP address
specified should match the system setting 10-12-01.
If connecting to an SV9100 system, select either IP or IP via
Dial-up or Outbound IP.
If connecting to an IPK II system, select either LAN, Direct or
Modem.
- Connection
Accounts).
To install dial up connection, refer to paragraph
SV9100 Dial Up Connection on page
ISSUE 2.0
2.2.2 Create