6-2-7 Housing Lower Assembly

1. Before you remove the Housing Lower
Assembly, you should remove:
- Rear Cover (see page 6-26)
- Scanner Assembly (see page 6-27)
- OPE Assembly (see page 6-29)
- ADF Upper Assembly (see page 6-31)
- Guide Lower Assembly (see page 6-32)
2. Unplug two connectors and the FFC Cable
from the Scan Board.
3. Remove seven screws securing the ADF
Lower Assembly.
6-34
4. Unlatch the Exit Roller gear part and remove
it, as shown below.
5. Unlatch the Scan Roller gear part and remove
it, as shown below.
6. Unlatch the ADF Roller gear part and remove
it, as shown below.