Main Frame Assembly - Xerox WorkCentre Pro 412 Service Manual

Hide thumbs Also See for WorkCentre Pro 412:
Table of Contents

Advertisement

Disassembly and Reassembly

6-1-12 Main Frame Assembly

1. Before you remove the LSU, you should
remove:
- Rear Cover (see page 6-2)
- Scanner Assembly (see page 6-3)
- Side Cover Assembly (see page 6-10)
- Fuser (see page 6-12)
- Exit Assembly (see page 6-13)
- Cover Paper Exit Assembly (see page 6-14)
- SMPS (see page 6-16)
- LSU (see page 6-17)
2. Remove one screw in the Channel Base
Frame from the bellow section of the Base
Frame, and then remove the rest of the five
screws to dissemble the Dummy Base
Frame, the Cover Front and the Cam Jam
Remove.
Front Cover
3. Remove the Locker Deve, and then remove
the one screw and the Cover Motor Bracket.
Lock Deve
6-18
Dummy Base Frame
Cam Jam Remove
Cover Motor Bracket
3/03
4. Unplug the all connectors.
5. Remove the seven screws and take out the
Main Frame Assembly.
WorkCentre Pro 412, FaxCentre F12 &
Main Frame Ass'y