Viewing email notification settings

The ibrix_event -L command provides comprehensive information about email settings and
configured notifications.
ibrix_event -L
Email Notification
SMTP Server
From
Reply To
EVENT
-------------------------------------
asyncrep.completed
asyncrep.failed

Setting up SNMP notifications

StoreAll software supports SNMP (Simple Network Management Protocol) V1, V2, and V3.
Whereas SNMPV2 security was enforced by use of community password strings, V3 introduces
the USM and VACM. Discussion of these models is beyond the scope of this document. Refer to
RFCs 3414 and 3415 at
In the SNMPV3 environment, every message contains a user name. The function of the USM
is to authenticate users and ensure message privacy through message encryption and
decryption. Both authentication and privacy, and their passwords, are optional and will use
default settings where security is less of a concern.
With users validated, the VACM determines which managed objects these users are allowed
to access. The VACM includes an access scheme to control user access to managed objects;
context matching to define which objects can be accessed; and MIB views, defined by subsets
of IOD subtree and associated bitmask entries, which define what a particular user can access
in the MIB.
Steps for setting up SNMP include:
Agent configuration (all SNMP versions)
Trapsink configuration (all SNMP versions)
Associating event notifications with trapsinks (all SNMP versions)
View definition (V3 only)
Group and user configuration (V3 only)
StoreAll software implements an SNMP agent that supports the private StoreAll software MIB. The
agent can be polled and can send SNMP traps to configured trapsinks.
Setting up SNMP notifications is similar to setting up email notifications. You must associate events
to trapsinks and configure SNMP settings for each trapsink to enable the agent to send a trap
when an event occurs.
NOTE:
When Phone Home is enabled, you cannot edit or change the configuration of the StoreAll
SNMP agent with the ibrix_snmpagent. However, you can add trapsink IPs with
ibrix_snmptrap and can associate events to the trapsink IP with ibrix_event.
72
Configuring cluster event notification
:
Enabled
:
mail.hp.com
:
FM@hp.com
:
MIS@hp.com
http://www.ietf.org
for more information. Note the following:
LEVEL
TYPE
DESTINATION
-----
-----
-----------
ALERT
EMAIL
admin@hp.com
ALERT
EMAIL
admin@hp.com