Moving The Fusion Manager Vif To Bond1 - HP StoreAll 9730 Administrator's Manual

Hide thumbs Also See for StoreAll 9730:
Table of Contents

Advertisement

4.
Unmount the file systems and continue with the upgrade procedure.

Moving the Fusion Manager VIF to bond1

When the 9720 system is installed, the cluster network is moved to bond1. The 6.1 release requires
that the Fusion Manager VIF (Agile_Cluster_VIF) also be moved to bond1 to enable access to ports
1234 and 9009. To move the Agile_Cluster_VIF to bond1, complete these steps:
1.
From the active Fusion Manager, list all passive management consoles, move them to
maintenance mode, and then unregister them from the agile configuration:
# ibrix_fm -f
nl
# ibrix_fm -m maintenance -A
nl
# ibrix_fm -u <management_console_name>
2.
Define a new Agile_Cluster_VIF_DEV and the associated Agile_Cluster_VIF_IP.
3.
Change the Fusion Manager's local cluster address from bond0 to bond1 in the StoreAll
database:
a.
Change the previously defined Agile_Cluster_VIF_IP registration address. On the active
Fusion Manager, specify a new Agile _Cluster_VIF_IP on the bond1 subnet:
ibrix_fm -t -I <new_Agile_Cluster_VIF_IP>
NOTE:
operation.
b.
On each file serving node, edit the /etc/ibrix/iadconf.xml file:
vi /etc/ibrix/iadconf.xml
In the file, enter the new Agile_Cluster_VIF_IP address on the following line:
<property name="fusionManagerPrimaryAddress"
value="xxx.xxx.xxx.xxx'/>
4.
On the active Fusion Manager, re-register all backup management consoles using the bond1
Local Cluster IP address for each node:
# ibrix_fm -R <management_console_name> -I <local_cluster_network_IP>
NOTE:
the hostname of the server.
5.
Return the backup management consoles to passive mode:
# ibrix_fm -m passive
6.
Place the active Fusion Manager into maintenance mode to force it to fail over. (It can take
up to a minute for a passive Fusion Manager to take the active role.)
# ibrix_fm -m maintenance -A
7.
Unregister the original active Fusion Manager from the new active Fusion Manager:
# ibrix_fm -u <original_active_management_console_name>
8.
Re-register that Fusion Manager with the new values and then move it to passive mode:
# ibrix_fm -R <agileFM_name> -I <local_cluster_network_ip>
nl
# ibrix_fm -m passive
9.
Verify that all management consoles are registered properly on the bond1 local cluster network:
# ibrix_fm -f
You should see all registered management consoles and their new local cluster IP addresses.
If an entry is incorrect, unregister that Fusion Manager and re-register it.
10. Reboot the file serving nodes.
184 Cascading Upgrades
The ibrix_fm -t command is not documented, but can be used for this
When registering a Fusion Manager, be sure the hostname specified with -R matches