HP StoreAll 9730 Administrator's Manual page 57

Hide thumbs Also See for StoreAll 9730:
Table of Contents

Advertisement

For example, you can create a user VIF that clients will use to access an SMB share serviced by
server ib69s1. The user VIF is based on an active physical network on that server. To do this, click
Add NIC in the section of the dialog box for ib69s1.
On the Add NIC dialog box, enter a NIC name. In our example, the cluster uses the unified network
and has only bond0, the active cluster FM/IP. We cannot use bond0:0, which is the management
IP/VIF. We will create the VIF bond0:1, using bond0 as the base. When you click OK, the user
VIF is created.
The new, active user NIC appears on the NIC HA setup dialog box.
Configuring High Availability on the cluster