To retry the copy of configuration, use the following command:
/usr/local/ibrix/autocfg/bin/ibrixapp upgrade -f -s
If the install of the new image succeeds, but the configuration restore fails and you need to
revert the server to the previous install, run the following command and then reboot the machine.
This step causes the server to boot from the old version (the alternate partition).
/usr/local/ibrix/setup/boot_info -r
If the public network interface is down and inaccessible for any node, power cycle that node.
NOTE:
Each node stores its ibrixupgrade.log file in /tmp.

Manual upgrade

Check the following:
If the restore script fails, check /usr/local/ibrix/setup/logs/restore.log for
details.
If configuration restore fails, look at /usr/local/ibrix/autocfg/logs/appliance.log
to determine which feature restore failed. Look at the specific feature log file under /usr/
local/ibrix/setup/logs/ for more detailed information.
To retry the copy of configuration, use the following command:
/usr/local/ibrix/autocfg/bin/ibrixapp upgrade -f -s

Offline upgrade fails because iLO firmware is out of date

If the iLO2 firmware is out of date on a node, the auto_ibrixupgrade script will fail. The /usr/
local/ibrix/setup/logs/auto_ibrixupgrade.log reports the failure and describes how
to update the firmware.
After updating the firmware, run the following command on the node to complete the StoreAll
software upgrade:
/local/ibrix/ibrixupgrade -f

Node is not registered with the cluster network

Nodes hosting the agile Fusion Manager must be registered with the cluster network. If the
ibrix_fm command reports that the IP address for a node is on the user network, you will need
to reassign the IP address to the cluster network. For example, the following commands report that
node ib51-101, which is hosting the active Fusion Manager, has an IP address on the user
network (192.168.51.101) instead of the cluster network.
[root@ib51-101 ibrix]# ibrix_fm -i
FusionServer: ib51-101 (active, quorum is running)
==================================================
[root@ib51-101 ibrix]# ibrix_fm -l
NAME
IP ADDRESS
--------
----------
ib51-101
192.168.51.101
ib51-102
10.10.51.102
1.
If the node is hosting the active Fusion Manager, as in this example, stop the Fusion Manager
on that node:
[root@ib51-101 ibrix]# /etc/init.d/ibrix_fusionmanager stop
Stopping Fusion Manager Daemon
[root@ib51-101 ibrix]#
22
Upgrading the StoreAll software to the 6.3 release
[
OK
]