Operation panel
4.1.3

Easy operation mode setting (easy setting mode)

Setting of Pr. 79 Operation mode selection according to combination of the start command and speed command can be
easily made.
Changing
Start command: external (STF/STR), frequency command: operate with
example
1.
Screen at powering on
The monitor display appears.
2.
Press
and
3.
Turn
until
(refer to the table below for other settings)
4.
Press
to set.
REMARKS
is displayed ... Why?
Parameter write is disabled with "1" set in Pr. 77.
is displayed ... Why?
Setting can not be made during operation. Turn the start switch (
Press
before pressing
operation mode when performed in the PU operation mode (PU JOG operation mode) and to PU operation mode when
performed in the external operation mode.
Reset can be made with
The priorities of the frequency commands when Pr. 79 = "3" are "Multi-speed operation (RL/RM/RH/REX) > PID control (X14) >
terminal 4 analog input (AU) > digital input from the operation panel".
52
Operation
for 0.5s.
appears.
Operation Panel Indication
Flickering
Flickering
Flickering
Flickering
Flickering
Flickering
Flickering
Flickering
to return to the monitor display without setting. In this case, the mode changes to external
.
Operation Method
Start command
Frequency command
External
Analog
(STF, STR)
voltage input
External
(STF, STR)
Analog
voltage input
Flicker ··· Parameter setting complete!!
The monitor display appears after
, STF or STR) OFF.
Display
Flickering
Flickering
Flickering
3s.