Wiring
2.1
Wiring
2.1.1

Terminal connection diagram

Sink logic
Main circuit terminal
Control circuit terminal
Single-phase power input
MCCB
Single-phase
AC power
supply
MCCB
Three-phase
AC power
supply
Control input signals (No voltage input allowed)
Forward
Terminal functions vary
rotation start
with the input terminal
Reverse
assignment (Pr. 178 to
rotation start
Pr. 182)
Multi-speed selection
*2 When using terminals PC-
SD as a 24VDC power
supply, take care not to
short across terminals
PC-SD.
(Common for external power supply transistor)
Frequency setting signals (Analog)
*3 Terminal input specifications
can be changed by analog
input specifications
switchover (Pr. 73).
Terminal 10 and terminal 2
are used as PTC input
terminal (Pr. 561).
*4 Terminal input
specifications can be
changed by analog input
specifications switchover
(Pr. 267). Set the
voltage/current input
switch in the "V" position
to select voltage input (0
to 5V/0 to10V) and "I"
(initial value) to select
current input (4 to 20mA).
*5 It is recommended to use 2W1kΩ
when the frequency setting signal
is changed frequently.
Safety stop signal
Output shutoff (Line 1)
Output shutoff (Line 2)
NOTE
To prevent a malfunction caused by noise, separate the signal cables more than 10cm (3.94inches) from the power
cables. Also separate the main circuit wire of the input side and the output side.
After wiring, wire offcuts must not be left in the inverter.
Wire offcuts can cause an alarm, failure or malfunction. Always keep the inverter clean. When drilling mounting holes
in an enclosure etc., take care not to allow chips and other foreign matter to enter the inverter.
The output of the single-phase power input specification is three-phase 200V.
14
*
1. DC reactor (FR-HEL)
MC
R/L1
Earth
S/L2
(Ground)
MC
R/L1
S/L2
T/L3
Earth
(Ground)
STF
STR
RH
High
speed
RM
Middle
speed
RL
Low
speed
SD
Contact input common
PC
24VDC power supply
10(+5V)
3
Frequency
setting
2 0 to 5VDC
2
potentiometer
(0 to 10VDC)
1/2W1kΩ
*5
5(Analog common)
1
Terminal 4
(+)
input
4 4 to 20mADC
(Current
(-)
input)
V
Voltage/current
input switch
Shorting
S1
wire
S2
SC
Common terminal
When connecting a DC reactor, remove the
jumper across P1-P/+
Single-phase 100V power input model is not
compatible with DC reactor.
Brake unit
(Option)
*1
R
*8
Jumper
PR N/-
*7
P1
P/+
*6
Inrush current
limit circuit
Main circuit
Control circuit
RUN
24V
*2
*3
PU
connector
0 to 5VDC
*4
0 to 10VDC
I
*4
Output shutoff
circuit
*6 Terminal P1 is not available for single-
phase 100V power input model.
*7 A brake transistor is not built-in to the
FR-D720-008, 014 and FR-D720S-008,
014 and FR-D710W-008, 014.
*8 Brake resistor (FR-ABR, MRS type, MYS
type)
Install a thermal relay to prevent an
overheat and burnout of the brake resistor.
(The brake resistor can not be connected
to the FR-D720-008, 014 and FR-D720S-
008, 014 and FR-D710W-008, 014.)
V
W
Relay output
C
Terminal functions vary
B
by Pr. 192 A,B,C terminal
Relay output
function selection
(Fault output)
A
Open collector output
Terminal functions vary by
Pr. 190 RUN terminal function
Running
selection
Open collector output common
SE
Sink/source common
(+)
AM
Analog signal output
5
(-)
SO
For manufacturer setting
Safety monitor output *8
*8 Common terminal of
terminal SO is terminal SC.
(Connected to terminal SD
inside of the inverter.)
Motor
IM
Earth (Ground)
(0 to 10VDC)