Parameter list
Func-
Parameter
Name
tion
—
564
Operating time carrying-over times
—
571
Holding time at a start
575
Output interruption detection time
576
Output interruption detection level
577
Output interruption cancel level
—
611
Acceleration time at a restart
—
653
Speed smoothing control
Regeneration avoidance frequency
—
665
gain
872
Input phase loss protection selection
∗8
Regeneration avoidance operation
882
selection
Regeneration avoidance operation
883
level
Regeneration avoidance compensation
885
frequency limit value
886
Regeneration avoidance voltage gain
888
Free parameter 1
889
Free parameter 2
Cumulative power monitor digit shifted
—
891
times
C1
AM terminal calibration
(901)
∗6
C2
Terminal 2 frequency setting bias
frequency
(902)
∗6
C3
Terminal 2 frequency setting bias
(902)
∗6
125
Terminal 2 frequency setting gain
frequency
(903)
∗6
C4
Terminal 2 frequency setting gain
(903)
∗6
C5
Terminal 4 frequency setting bias
frequency
(904)
∗6
C6
Terminal 4 frequency setting bias
(904)
∗6
126
Terminal 4 frequency setting gain
frequency
(905)
∗6
C7
Terminal 4 frequency setting gain
(905)
∗6
C22 to C25
—
Parameter for manufacturer setting. Do not set.
(922 to 923)
990
PU buzzer control
991
PU contrast adjustment
64
Minimum
Refer
Initial
Setting Range
Setting
to
Value
Increments
Page
(0 to 65535)
1
0
126
0 to 10s, 9999
0.1s
9999
96
0 to 3600s, 9999
0.1s
1s
210
0 to 400Hz
0.01Hz
0Hz
210
900 to 1100%
0.1%
1000%
210
0 to 3600s, 9999
0.1s
9999
134
0 to 200%
0.1%
0
147
0 to 200%
0.1%
100
224
0, 1
1
0
144
0, 1, 2
1
0
224
400VDC/
300 to 800V
0.1V
224
780VDC
∗5
0 to 10Hz, 9999
0.01Hz
6Hz
224
0 to 200%
0.1%
100%
224
0 to 9999
1
9999
234
0 to 9999
1
9999
234
0 to 4, 9999
1
9999
126
—
—
—
132
0 to 400Hz
0.01Hz
0Hz
151
0 to 300%
0.1%
0%
151
0 to 400Hz
0.01Hz
60Hz
151
0 to 300%
0.1%
100%
151
0 to 400Hz
0.01Hz
0Hz
151
0 to 300%
0.1%
20%
151
0 to 400Hz
0.01Hz
60Hz
151
0 to 300%
0.1%
100%
151
0, 1
1
1
239
0 to 63
1
58
239
Customer
Parameter
Remarks
Setting
564
571
575
576
577
611
653
665
872
882
883
885
886
888
889
891
C1
(901)
C2
(902)
C3
(902)
125
(903)
C4
(903)
C5
(904)
C6
(904)
126
(905)
C7
(905)
C22 to C25
Parameter for manufacturer setting. Do not set.
(922 to 923)
990
991
Control Mode-based
Instruction Code
Correspondence Table
Read
Write
Extended
Copy
V/F
V/F
V/F
GP MFVC
GP MFVC
GP MFVC
40
C0
5
47
C7
5
4B
CB
5
4C
CC
5
4D
CD
5
0B
8B
6
35
B5
6
41
C1
6
48
C8
8
52
D2
8
53
D3
8
55
D5
8
56
D6
8
58
D8
8
59
D9
8
5B
D8
8
5D
DD
1
5E
DE
1
5E
DE
1
5F
DF
1
5F
DF
1
60
E0
1
60
E0
1
61
E1
1
61
E1
1
5A
DA
9
5B
DB
9
Parameter list
Parameter
Clear
All clear
×
×
×
×
×
×
×
×
×
×
×
×
×
4
×
×
×
×