Mitsubishi Electric FR-D720-008 Instruction Manual page 211

Hide thumbs Also See for FR-D720-008:
Table of Contents

Advertisement

(6)
Modbus registers
System environment variable
Register
40002
Inverter reset
40003
Parameter clear
40004
All parameter clear
Parameter clear ∗1
40006
All parameter clear ∗1
40007
40009
Inverter status/control input instruction∗2
Operation mode/inverter setting ∗3
40010
40014
Running frequency (RAM value)
40015
Running frequency (EEPROM value)
∗1
The communication parameter values are not cleared.
∗2
For write, set the data as a control input instruction.
For read, data is read as an inverter operating status.
∗3
For write, set data as the operation mode setting.
For read, data is read as the operation mode status.
Inverter status/control input instruction
<
Bit
Control input instruction
0
Stop command
1
Forward rotation command
2
Reverse rotation command
RH (high-speed operation
3
command)∗1
RM (middle-speed operation
4
command)∗1
RL (low-speed operation
5
command)∗1
6
7
RT (second function selection)
8
AU (terminal 4 input selection)
9
10
MRS (output stop)
11
12
13
14
15
∗1
The signal within parentheses is the initial setting. Definitions change according to the Pr. 180 to Pr. 182 (input terminal function selection) (refer to
page 111).
Each assigned signal is valid or invalid depending on NET. (Refer to page 174)
∗2
The signal within parentheses is the initial setting. Definitions change according to the Pr. 190, Pr. 192 (output terminal function selection) (refer to page117).
Real time monitor
Refer to page 126 for details of the monitor description.
Register
40201
Output frequency/speed
40202
Output current
40203
Output voltage
Output frequency setting/speed
40205
setting
40208
Converter output voltage
40209
Regenerative brake duty
Electronic thermal relay function
40210
load factor
40211
Output current peak value
40212
Converter output voltage peak value
40214
Output power
Input terminal status ∗2
40215
∗1
When Pr.37 = "0.01 to 9998", displayed in integral number.
∗2
Input terminal monitor details
b15
∗3
Output terminal monitor details
b15
Definition
Definition
Inverter status
RUN (inverter running) ∗2
Forward rotation
During reverse rotation
SU (up-to-frequency)
OL (overload)
0
FU (frequency detection)
ABC (fault) ∗2
0
0
0
0
0
0
Fault occurrence
Description
Unit
0.01Hz/1 ∗1
0.01A
0.1V
0.01Hz/1 ∗1
0.1V
0.1%
0.1%
0.01A
0.1V
0.01kW
Communication operation and setting
Read/write
Write
Any value can be written
Write
Set H965A as a written value.
Write
Set H99AA as a written value.
Write
Set H5A96 as a written value.
Write
Set HAA99 as a written value.
Read/write
See below.
Read/write
See below.
According to the Pr. 37 settings, the frequency
Read/write
and selectable speed are in 1r/min
Write
increments.
Operation mode/inverter setting
>
<
Mode
EXT
PU
EXT
JOG
NET
PU+EXT
The restrictions depending on the operation
0
mode changes according to the computer
link specifications.
0
0
0
0
0
0
0
Register
Output terminal status ∗3
40216
40220
Cumulative energization time
40223
Actual operation time
40224
Motor load factor
40225
Cumulative power
40252
PID set point
40253
PID measured value
40254
PID deviation
40261
Motor thermal load factor
40262
Inverter thermal load factor
40263
Cumulative power 2
40264
PTC thermistor resistance
RH
RM
ABC
Remarks
>
Written
Read Value
Value
H0000
H0010
H0001
H0002
H0004
H0014
H0005
Description
Unit
1h
1h
0.1%
1kWh
0.1%
0.1%
0.1%
0.1%
0.1%
0.01kWh
0.01kΩ
RL
STR
4
b0
STF
b0
RUN
207