NEC EXPRESS5800/100 SERIES N8100-1635F User Manual page 70

Express5800/100 series
Table of Contents

Advertisement

4-18 Configuring Your Modular Server
Option
Thermal Sensor
BMC IRQ
Post Error Pause
AC-LINK
Power ON Delay
Time
Platform Event
Filtering
The table below shows the operation when the AC power to the modular server is turn off once and
then on again, depending on the setting of "AC-LINK".
System status before AC power off
Operating
Aborting (DC power being off also)
Forced shutdown*
* Press the POWER/SLEEP switch continuously for four seconds or longer. This forcibly turns off
the power.
Parameter
Disabled
[Enabled]
Disabled
[IRQ 11]
Disabled
[Enabled]
Shamrock-G
Stay Off
[Last State]
Power On
Default [t1] (s)
[t1-255] (s)
Disabled
[Enabled]
Description
Specify whether the temperature
sensor monitoring feature is
enabled or disabled. If a thermal
error is detected with this item
being set to "Enabled", the system
stops at the end of POST.
Specify whether to assign IRQ for
BMC (Baseboard Management
Controller).
Specify whether POST is aborted
once at the end of POST if an error
occurs during the execution of
POST.
Specify the AC-LINK feature.
Shows the system status when the
AC power is supplied again to the
modular server. See the table
below.
Specify the power-on delay time
between 1 and 255 seconds. This
option is available only when
"Power On" or "Last State" is
specified for AC LINK.
Specify whether the Platform
Event Filtering feature of the
Baseboard Management
Controller (BMC) is enabled or
disabled.
Setting of AC-LINK
Stay Off
Last State
Off
On
Off
Off
Off
Off
Your Setting
[
]: Factory-set
Power On
On
On
On