Proc 1.05v Alm 02
Proc 1.05v Alm 09
Proc Core Alm 02
Proc Core Alm 09
Proc Missing
Description
1.05V voltage alarm
(lower limit) occurred on
processor.
1.05V voltage alarm
(upper limit) occurred on
processor.
A core voltage alarm
(lower limit) was detected
in processor.
A core voltage alarm
(upper limit) was detected
in processor.
No processor is installed.
Action
1. Take one of the following measures to power
off the modular server and then on.
* Power off the modular server from OS,
then press the POWER/SLEEP switch to
power on.
* Press the POWER/SLEEP switch to power
off the modular server, then press it again
to power on.
* Issue a command from Web browser of
EXPRESSSCOPE Engine or NEC
ESMPRO Manager.
2. Power off the modular server by issuing an
OS command or press the POWER/SLEEP
switch. Take the modular server out of the
Module Enclosure, and install it again. Then,
press the POWER/SLEEP switch to turn on
the modular server.
3. Check installation status of the heat sink of
the modular server.
4. If the same error persists, contact your
service representative.
Contact your service representative.
Troubleshooting 7-21