Messages displayed on lower line
When STATUS lamp is off:
On-screen
message
SMI Timeout
DUMP Request!
Description
A timeout error occurred
during system
management interrupt.
DUMP switch was
pressed.
Action
1. Take one of the following measures to
reboot (reset) the modular server.
* Issue an OS command.
* Press Ctrl + Alt + Del.
* Issue a command from Web browser of
EXPRESSSCOPE Engine or NEC
ESMPRO Manager.
2. Take one of the following measures to power
off the modular server and then on.
* Power off the modular server from OS,
then press the POWER/SLEEP switch to
power on.
* Press the POWER/SLEEP switch to power
off the modular server, then press it again
to power on.
* Issue a command from Web browser of
EXPRESSSCOPE Engine or NEC
ESMPRO Manager.
3. Power off the modular server by issuing a
command from OS or pressing the
POWER/SLEEP switch. Remove the
modular server from Module Enclosure, then
install it again. Then press the
POWER/SLEEP switch to power on the
modular server.
4. If the same error persists, contact your
service representative.
Wait until OS dump process completes.
1. If the dump process is not complete, take
one of the following steps.
* Issue a command from OS.
* Press Ctrl + Alt + Del.
* Issue a command from Web browser of
EXPRESSSCOPE Engine or NEC
ESMPRO Manager.
2. Take one of the following measures to power
off the modular server and then on.
* Power off the modular server from OS,
then press the POWER/SLEEP switch to
power on.
* Press the POWER/SLEEP switch to power
off the modular server, then press it again
to power on.
* Issue a command from Web browser of
EXPRESSSCOPE Engine or NEC
ESMPRO Manager.
3. If the same error persists, contact your
service representative.
Troubleshooting 7-15