7-20 Troubleshooting
On-screen
message
BB 1.8v Alm 02
BB 1.8v Alm 09
BB 0.9v Alm 02
BB 0.9v Alm 09
BB 1.5v Alm 02
BB 1.5v Alm 09
BB 3.3v Alm 02
BB 3.3v Alm 09
BB 5.0v Alm 02
BB 5.0v Alm 09
BB 12v Alm 02
BB 12v Alm 09
BB 1.2vsb Alm 02
BB 1.2vsb Alm 09
BB 3.3vsb Alm 02
BB 3.3vsb Alm 09
Description
1.8V voltage alarm (lower
limit) occurred.
1.8V voltage alarm (upper
limit) occurred.
0.9V voltage alarm (lower
limit) occurred.
0.9V voltage alarm (upper
limit) occurred.
1.5V voltage alarm (lower
limit) occurred.
1.5V voltage alarm (upper
limit) occurred.
3.3V voltage alarm (lower
limit) occurred.
3.3V voltage alarm (upper
limit) occurred.
5.0V voltage alarm (lower
limit) occurred.
5.0V voltage alarm (upper
limit) occurred.
12V voltage alarm (lower
limit) occurred.
12V voltage alarm (upper
limit) occurred.
1.2Vsb voltage alarm
(lower limit) occurred.
1.2Vsb voltage alarm
(upper limit) occurred.
3.3Vsb voltage alarm
(lower limit) occurred.
3.3Vsb voltage alarm
(upper limit) occurred.
Action
1. Take one of the following measures to power
off the modular server and then on.
* Power off the modular server from OS,
then press the POWER/SLEEP switch to
power on.
* Press the POWER/SLEEP switch to power
off the modular server, then press it again
to power on.
* Issue a command from Web browser of
EXPRESSSCOPE Engine or NEC
ESMPRO Manager.
2. Power off the modular server by issuing an
OS command or press the POWER/SLEEP
switch. Take the modular server out of the
Module Enclosure, and install it again. Then,
press the POWER/SLEEP switch to turn on
the modular server.
3. If the same error persists, contact your
service representative.