7.7) Diagnostics and Signals

A few devices issue special signals that allow you to recognize the
operating status or possible malfunctions.

7.7.1) Signalling with flashing light and courtesy light

During the manoeuvre the flashing light, if connected, flashes once every second. When something is wrong the flashes are more frequent;
the light flashes twice with a second's pause between flashes. The courtesy light gives the same diagnostics signals.
Table 22: FLASH flashing light signalling
Quick flashes
2 flashes
1 second's pause
2 flashes
3 flashes
1 second's pause
3 flashes
4 flashes
1 second's pause
4 flashes
5 flashes
1 second's pause
5 flashes
6 flashes
1 second's pause
6 flashes
7 flashes
1 second's pause
7 flashes

7.7.2) Signals on the control unit

On the SPIN control unit there is a set of LED's each of which can
give special indications both during normal operation and in case of
malfunctions.
Table 23: LED's on the control unit's terminals
OK LED
Off
On
One flash every second
2 Quick flashes
Series of flashes separated by
a second's pause
STOP LED
Off
On
24
Cause
Triggering of a photocell
Activation of the "motor force"
limiting device
Activation of the STOP input
Error in the internal
parameters of the electronic
control unit
The maximum manoeuvre
limit/hour has been exceeded
There is an error in the
internal electric circuits
Cause
Malfunction
Serious malfunction
Everything OK
The status of the inputs has
changed
Miscellaneous
Cause
Activation of the STOP input
Everything OK
ACTION
At the starting of the manoeuvre, one or more photocells do not enable it;
check to see if there are any obstacles.
This is normal when there is an obstacle impeding the closing movement.
During the movement, the door experienced excessive friction; identify the
cause.
During the movement the STOP input was activated; identify the cause
Wait at least 30 seconds, then try giving a command; if the condition persists it
means there is a serious malfunction and the electronic board has to be
replaced.
Wait for a few minutes until the manoeuvre limiting device drops to under the
maximum limit.
Disconnect all the power circuits for a few seconds and then try giving a
command again; if the condition persists it means there is a serious fault on the
electronic board or the motor cabling. Check and replace as necessary.
44
ACTION
Make sure there is power supply; check to see if the fuses are blown; if
necessary, identify the reason for the failure and then replace the fuses with
others having the same characteristics.
There is a serious malfunction; try switching off the control unit for a few
seconds; if the condition persists it means there is a malfunction and the
electronic board has to be replaced.
Normal operation of control unit
This is normal when there is a change in one of the inputs: Step-by-Step,
STOP, triggering of photocells or the radio transmitter is used
It corresponds to the flashing light or the courtesy signal. See Table 22
ACTION
Check the devices connected to the STOP input
STOP Input active