7.2.3) LEVEL 2 functions (adjustable parameters)
Table 17: List of level 2 programmable functions in "Programming on power-up" mode
Input leds
Parameter
Sensitivity
L1
variable
Belt recovery
L2
Closing
L3
slowdown
Note: "
" Represents factory settings.
Table 17a: List of level 2 programmable functions in "Standard programming" mode
Input leds
Parameter
L1
Motor force
L2
SS function.
L3
Pause Time
Note: "
" Represents factory settings.
All parameters can be adjusted as required without any contraindications, only the "Motor force" setting may require special attention:
• Use of high force values are not recommended to compensate for the fact that the leaf has anomalous points of friction; excessive force
may impair the safety system and damage the leaf.
• If the "Motor force control" is used in support of the system for impact force reduction, after each adjustment the force measurement pro-
cedure must be performed, as envisaged by standard EN 12445.
• Wear and atmospheric conditions influence movement of the gate; force settings should be checked periodically.
7.2.4) Level 2 programming (adjustable parameters)
By default the settable parameters are set as shown in Tables 17 and 17a with: "
18 and 18a. Take care during modification procedures, as there is a maximum time interval of 10 seconds between pressing one key and
another; otherwise the system exits the procedure automatically memorising the changes made up to that time.
Table 18: To modify the adjustable parameters in "programming on power-up" mode
1.
Switch off SPIN (for example by removing fuse F1)
2.
Press and hold [Set]
3.
Switch on SPIN (for example by inserting fuse F1)
4.
Wait for the flashing signal indicating control unit start-up and keep [Set] pressed until L1 starts to flash
(approx. 6s)
5.
Release the key [Set] when led L1 starts to flash
6.
Press key [
] to move the flashing led to the "input led" associated with the parameter to be
modified
7.
Press and hold [Set] during steps 5 and 6
8.
Wait approx. 3s after which the led associated with the current level of the parameter to be modified
will light up
9.
Press key [
] to move the led associated with the parameter value.
10.
Release [Set]
11.
Wait 10s to exit the programming mode automatically after the maximum time interval.
Note: Points 6 to 10 can be repeated during the same programming phase to modify other parameters
18
Led (level)
Value
L1
High
L2
Medium
L3
Low
L1
No recovery
L2
Minimum recovery
L3
Maximum recovery
L1
Short
L2
Medium
L3
Long
Led (level)
Value
L1
Low
L2
Medium
L3
High
L1
Open, Stop, Close, Open
L2
Open, Stop, Close, Stop
L3
Apartment block
L1
15 seconds
L2
30 seconds
L3
60 seconds
Description
When variable sensitivity is enabled, it can be set to three dif-
ferent activation thresholds. "High" variable sensitivity is most
suited to small size correctly balanced doors.
Sets the belt recovery value. After complete closure of the
door, a very brief opening manoeuvre is activated, settable
with this parameter.
Sets the slowdown time interval during the closing manoeuvre.
Description
Sets the maximum force generated by the motor to
move the door.
Adjusts the sequence of commands associated with
the SS input or the 1st radio command (see tables 7
and 8).
Adjusts the pause time, i.e. time before automatic re-
closure. Is effective only if automatic closure is enabled
" but can be modified at any time as shown in Tables
Example
SET
L1
6s
SET
L1
SET
SET
3s
SET
10s