9.10 - DIAGNOSTICS AND DEVICE SIGNALS
9.10.1 - Photocell signals
The photocells contain a SAFE led (Fig. 6/A )
SAFE led (Fig. 6/A)
Status
O
The photocell is not powered or is
faulty
Device not recognised by the control
second pause
unit
The RX receives an excellent signal
The RX receives a good signal
The RX receives a poor signal
The RX receives a bad signal
Always lit
The RX does not receive any signal
02.
1
2
1
3
Action
ge is correct, the photocell is probably faulty
Repeat the recognition procedure on the control unit. Check that all pairs of pho -
tocells on the ECSBus have di erent addresses (consult the instruction manual of
the photocells)
Normal operation
Normal operation
Normal operation but check TX-RX alignment and correct cleaning of photocell lenses
photocell lenses
Check for any obstruction between TX and RX. Check that the Led on TX emits a