7) Further information
This chapter deals with the options for programming, personalisation, diagnostics and troubleshooting for the SPIN gearmotor.

7.1) Programming keys

The SPIN control unit is fitted with 3 keys which can be used both for the control of
the unit during testing and the programming procedure:
RADIO
Within the first 10 seconds after power-up, perform the "RADIO" function to
enable memorisation and deletion of the radio transmitters used with SPIN.
After this time interval, the key is no longer used.
Stop
The STOP key stops the manoeuvre; if pressed for more than 5 seconds,
SET
it enables entry to programming mode as described below.
SS
The SS key enables door opening and closing commands; otherwise this key
can be used to scroll up through the programming steps.

7.2) Programming

The SPIN control unit is equipped with a number of programmable
functions; function settings are entered by means of the 2 keys on
the control unit: [
] and [Set] and are displayed by means of 3
leds: L1, L2, L3.
There are two types of programming:
Programming on power-up: This type of programming can be
performed only immediately after switching on SPIN. Press and hold
[Set] during power-up of the control unit to activate this program-
ming mode.
Standard programming: This programming mode can be used at
any time and is activated by pressing and holding [Set].
7.2.1) Level 1 functions (ON-OFF functions)
Table 15: List of programmable functions in "Programming on power-up" mode
Description
L1
Variable Sensitivity
L2
Phototest/Electric block
L3
Partial open
At the end of the "Programming on power-up" procedure, leds L1, L2 and L3 indicate the status of the functions in "Standard pro-
gramming" mode.
Table 15a: List of programmable functions in "Standard programming" mode
Description
L1
Closing speed
L2
Opening speed
L3
Automatic closure
During normal operation of SPIN, leds L1, L2 and L3 are lit or off depending on the status of the associated function in Standard pro-
gramming mode, for example L3 is lit if the function "Automatic closure" is enabled. L1 also displays the status of the "radio" function in
the first 10 seconds after power-up.
16
Example
This function enables the user to enable or disable sensitivity with which obstacles are detected.
The factory setting of sensitivity is variable (led L1 off): Greater sensitivity in the case of low motor force,
and less sensitivity where the motor force increases. All with the aim of ensuring optimal detection
precision. Variable sensitivity can be disabled, and 3 "fixed" levels of motor force remain (led L1 lit).
This function enables the user to enable output 8 of the terminal board for operation with Phototest or
with an Electric block. The factory setting of output 8 is with the "phototest" function enabled (led L2 off).
Alternatively the output can be programmed on the SPIN control unit for control of an electric block
(led L2 lit).
This function enables the selection of a long or short partial opening interval. The factory setting for
partial open is long (approx. 1 m, led L3 lit). Alternatively partial open can be set to short (approx. 15cm,
led L3 off).
Example
This function enables the selection of the motor speed during the closing manoeuvre, from 2 levels:
"high" and "low". The factory setting is "high" (led L1 lit). Alternatively the function can be disabled to set
the "low" speed (led L1 off).
This function enables the selection of the motor speed during the opening manoeuvre, from 2 levels:
"high" and "low". The factory setting is "high" (led L2 lit). Alternatively the function can be disabled to set
the "low" speed (led L2 off).
This function enables automatic closure of the door after a programmed pause; the default Pause Time
is set at 30 seconds but may be modified to 15 or 60 seconds. The factory setting is "semiautomatic"
as Automatic closure is disabled (led L3 off).
37
For both modes, the programming and programmable functions
available are divided into 2 levels:
Level 1: functions settable in ON-OFF mode (enabled or disabled);
in this case leds L1, L2, and L3 indicate a function, if lit the function
is enabled, if off the function is disabled; see Tables 15 and 15a.
Level 2: parameters settable on a scale of values (from 1 to 3); in
this case each led L1, L2, L3 indicates a set value from the possi-
ble 3; see Tables 17 and 17a.