Omron CQM1H series Operation Manual page 31

Hide thumbs Also See for CQM1H series:
Table of Contents

Advertisement

Nomenclature
CQM1-B7A13
Front View
Indicators
Terminal screws: M3
(Optimum tightening torque: 0.5 N S m)
Name
RDY
Unit ready
3ms
Transmission
delay time
LOAD OFF
Transmission
error
processing
15IN+ERR
Input mode
ERR1
Input 1
transmission
error
ERR2
Input 2
transmission
error
Indicators (see following table)
B7A Link Terminal connection terminals 1
For connection of a 16-point Input B7A Link Terminal.
Inputs least-significant word (n) data.
B7A Link Terminal connection terminals 2
For connection of a 16-point Input B7A Link Terminal.
Inputs most-significant word (n+1) data.
External power terminals
Required for transmission with the B7A Link Terminal. Con-
nect a 12- to 24-VDC power supply.
Color
Green
Lit while the CQM1H/CQM1 is supplied
with power.
Orange
Lit while transmission delay time is set
to RAPID (3 ms). Not lit when set to
STANDARD (19.2 ms).
Orange
Lit while transmission error processing
is set to LOAD OFF. Not lit when set to
HOLD.
Orange
Lit while input mode is set to 15IN+ERR.
Not lit when set to 16IN.
Red
Lit when normal transmission with the
Input B7A Link Terminal connected to
connection terminals 1 is not possible or
when no Input B7A Link Terminal is
connected.
Red
Lit when normal transmission with the
Input B7A Link Terminal connected to
connection terminals 2 is not possible or
when no Input B7A Link Terminal is
connected.
Section 2-1
Function
11