Operation without CQM1-TU001 Remote Console
Teaching with a Sensing
Object
1, 2, 3...
Teaching for Position
Control
1, 2, 3...
150
The ON point will be automatically set at the maximum value of the stable
sensing distance. If teaching is unsuccessful, the stability operation indica-
tor will flash. In this case make sure that the optical fiber cable of the sensor
is connected securely and that there is no sensing object, and then repeat
from step 3.
Teaching with a sensing object is recommended for sensing level differences or
double-sheet detection.
1. Place the sensor head in the sensing range of the sensor.
2. Set the mode selector to SET.
3. Place the object at the sensing position at which the desired output will be
OFF and press the teaching button.
The teaching indicator will turn orange.
4. Move the object to the position where you want to turn ON the output and
press the teaching button. If teaching is successful, the teaching indicator
will turn from orange to green.
5. Set the mode selector to RUN to complete the sensitivity setting on the E3X-
MA11. The ON point will be set midway between the points set in steps 3.
and 4. If teaching is unsuccessful, the teaching indicator (orange) will flash,
in which case check that the sensor cable is connected, change the position
of the object and the sensing distance that have been set, and repeat from
step 3.
Note The sensor may not properly reset after detection when teaching detection of
subtle changes. Always check to be sure the sensor is resetting even if the indi-
cator shows that teaching is OK.
Teaching for position control is recommended when specifying the ON point for
the detection of objects which are too close.
1. Place the sensor head in the sensing range of the sensor.
2. Set the mode selector to SET.
3. Press the teaching button. The teaching indicator (orange) will be lit.