Download Print this page
Omron SC20G2 Installation Instruction
Omron SC20G2 Installation Instruction

Omron SC20G2 Installation Instruction

Nmp/web card
Hide thumbs Also See for SC20G2:

Advertisement

Quick Links

SNMP/Web Card Installation Instruction
About CD enclosed to this product
① The kind and version of inclusion software are changed without a preliminary announcement in
the software recorded on CD enclosed for this product.
Please confirm CD enclosed to goods about the software recorded on CD.
② About automatic shutdown software, the latest version and a previous version are downloadable
from our homepage.
【Homepage address】
http://Industrial.omron.eu/, http://www.fa.omron.com.cn/
Safety attention
In order to prevent an injury, failure, a fire, etc., please be sure to read notes currently explained
here.
● The sign and meaning about the safety of this operation manual are as follows.
attention
※ Physical loss or damage means the expansion damage concerning a house
and household effects, livestock, and a pet.
:It means prohibition (it must not carry out).
For example,
: It means compulsion (it must carry out).
For example,
In addition, depending on a situation, it may be connected with a serious result also under
the matter indicated to cautions. Since all have indicated important contents, please be sure
to comply.
SNMP/Web Card Install Guide
If the mistaken handling is carried out, people get injured or the
contents generating of physical loss or damage is assumed to be
are shown.
means the ban on decomposition.
means being connected by the ground.
1

Advertisement

loading

Summary of Contents for Omron SC20G2

  • Page 1 ② About automatic shutdown software, the latest version and a previous version are downloadable from our homepage. 【Homepage address】 http://Industrial.omron.eu/, http://www.fa.omron.com.cn/ Safety attention In order to prevent an injury, failure, a fire, etc., please be sure to read notes currently explained here.
  • Page 2 注意 When you perform insertion and removal of this product , be sure to turn off the main part of an uninterruptible power supply (UPS) and connection apparatus, and to carry out in the state "AC input" plug is pulled out from a power receptacle. ●...
  • Page 3 注意 A battery is not used for other uses. Do not disassemble, heated or dispose of in a fire。 ● There is a risk of starting a burst and a fire. + and - of a battery are not short-circuited with wire etc. ●...
  • Page 4 Please check whether there is any damage in the appearance of this product, or all the following packing articles are included. * When a packing article has fault and shortage, please ask the store of a purchase, or the OMRON electronic device customer support center.
  • Page 5 Exchange of a bracket Brackets are exchanged if needed. ● Replacement is unnecessary when connecting to BU50SW/BU75SW/BU100SW/BU150SW, BU1002SW/BU3002SW, BU75RW/BU100RW/ BU200RW/BU300RW, BU60RE/BU100RE,BU150R,BN75R/BN150R/BN300R, BN50T/BN75T/BN100T/BN150T/BN220T/BN300T,BU1002RW, BU2002RWL/BU3002RWL/BU5002RWL,BU1002SWG/BU3002SWG, BU1002SWCL/BU3002SWCL,BU2002RWLG/BU3002RWLG/BU5002RWLG BU50SW/BU75SW/BU100SW/BU150SW, BU1002SW/ BU3002SW, BU75RW/BU100RW/BU200RW/BU300RW, BU60RE/BU100RE,BU150R,BN75R/BN150R/BN300R, BN50T/BN75T/BN100T/BN150T/BN220T/BN300T, BU1002RW/BU2002RWL/ BU3002RWL/BU5002RWL, BU1002SWG/BU3002SWG, BU1002SWCL/BU3002SWCL, BU2002RWLG/ BU3002RWLG/BU5002RWLG ● Please exchange for an attached exclusive bracket when you connect it with BN150XR Bracket for BN150XR Bracket for BU50SW/BU75SW/BU100SW/BU150SW, BU1002SW/ BU3002SW,BU75RW/BU100RW/...
  • Page 6 Insertion of a SNMP/Web card . Please check that the power of an uninterruptible power supply (UPS) is off, and that it is in the state where AC input cable was removed from the electric socket or the terminal board, and electric power is off.
  • Page 7 Insert to the slot of Insert to the slot of Insert to the slot of Insert to the slot of BU2002RWL/BU3002RWL/ BN50T/BN75T BN100T/BN150T BN220T/BN300T BU2002RWLG/BU3002RWLG/ BU5002RWLG . Please connect an uninterruptible power supply (UPS) with a power receptacle, and turn ON a "power"...
  • Page 8 A network setup of a SNMP/Web card A setup for using this product on the target network is performed. The fixed IP address of the initial value of this product is set as "192.168.2.150." Please make a change of a fixed IP address from [SMNP-Web-Card Configuration Utility Main menu] of a "method 1: via serial port"...
  • Page 9 . Since the screen for setting up the property of the set-up COM port is displayed, please set up as follows. Port Com1 Bits per second 9600 Data bits Parity None Stop bits 1 bit Flow control None . A click of [OK] will set up the screen of Tera Term. The screen of Tera Term .
  • Page 10 . The item of [SNMP-Web-Card Configuration Utility Main menu] is displayed. If "1" is inputted and is pushed, [SNMP-Web-Card Configuration Menu] will be displayed. . Furthermore, please input "1" and push . [System Group Configuration Menu] is displayed and the list of the network-related present preset values of a SNMP/Web card is displayed.
  • Page 11 . Please operate it according to a display and end a setting menu. . Click the [file] of a menu bar and click [exit]. It is possible to set up almost all functions via a serial port except for a shutdown-related function. Please refer to the operation manual in enclosed CD-ROM for the details of the contents of a setting.
  • Page 12 . Please click a [property] after choosing [the Internet protocol version 4 (TCP/IP)]. .Check [Use the following address]. Please set up the IP address column, the subnet mask column, and the default gateway column as follows, and click [OK]. IP address:192.168.2.aaa Subnet mask:255.255.255.0 Default gateway : 192.168.2.1 Please put the arbitrary number of 1~254 into aaa.
  • Page 13 <A setup of this product> . Please connect the SNMP/Web card inserted in the uninterruptible power supply(UPS) to a network. . Next, please perform a Windows command prompt according to the following procedures. [Start] -> [Command prompt] . The following command prompt screens are displayed. .
  • Page 14 . Next, please input "admin " in a password entry screen. . Subsequent setup steps are the same as that of the case "method 1:Via a serial port." Please perform a setup from the following screens. Please return a network setup of the computer for a setup if needed. SNMP/Web Card Install Guide...
  • Page 15 Reference: Via Web browser When a setup of an IP address is finished via a serial port course and Telnet, and acquiring an IP address from a DHCP server, this product can be set up from a web browser. . Please connect the SNMP/Web card inserted in the uninterruptible power supply (UPS) to a network.
  • Page 16: Specification

    SNMP、 HTTP、 HTTPS、 SSH、 ARP、 RARP、 TFTP、 ICMP、Telnet Other communication pathways Serial connection,Asynchronous system (only setup) Support MIB UPSMIB(RFC1628) OMRON MIB 0 ~ 40℃ Operating temperature 10 ~ 80% Operating humidity BU50SW 、 BU75SW 、 BU100SW 、 BU150SW 、 Correspondence uninterruptible power supply (UPS) BU1002SW、BU3002SW、BU75RW、BU100RW、...
  • Page 17 安全注意事项 请务必熟读本文所述注意事项,以防止受伤、故障、火灾等的发生。 ●本使用说明书中的相关安全符号及其含义如下所述。 注意 表示操作失误可能会导致人身伤害、物质损失的内容。 ※ 所谓物质损失,是指房屋、家产以及家畜、宠物相关的连带损失。 : 表示禁止(不可发生的行为)。例如 表示禁止擅自拆卸。 : 表示强制(必须的行为)。例如 表示必须进行接地连接。 此外,即使注意事项中已进行提醒,也可能因不同的状况而导致重大事故发生。 上述注意事项均为重要内容,请务必遵守。...
  • Page 18 注意 装卸本产品时,请务必切断不间断电源(UPS)主机及其连接设备的电源,并从电 源插座上拔去“AC 输入”插头后再执行操作。 ● 否则有触电的危险。 不得擅自拆卸、维修、改造。 ● 否则可能导致触电、火灾的危险。 在不间断电源(UPS)上装卸本产品时,请务必将不间断电源(UPS)以不会翻倒的朝 向设置于平坦稳定的场所后再执行操作。 ● 否则一旦翻倒或掉落可能导致受伤。 安装了本产品的不间断电源(UPS)应正确进行接地连接。 ● 若未进行接地连接,一旦同时接触不间断电源(UPS)和其他设备,则可能导致触电的危 险。 装卸本产品时,不得接触电路板端面或电路板上的元件。 ● 电路板端面或元件非常锋利,一旦接触则可能导致受伤的危险。 ● 元件进入高温状态后可能导致烫伤的危险。 ● 本产品使用了对静电反应灵敏的元件。尤其请勿直接用手触摸连接器的接点端口及其 他元件。 即使内部电路板上附着了液体,也不得触摸该液体。 ● 否则可能会导致失明或烫伤的危险。 ● 若接触到眼睛或皮肤,请立即用水充分冲洗,并接受医生的诊治。 本产品一旦出现冒烟、 异味、 异响现象, 应立即切断连接的不间断电源(UPS)“电 源”开关,并从电源插头上拔去“AC 输入”插头。 ● 一旦出现此种现象,请务必立即停止使用,并委托购买产品的店铺或本公司进行检修。 请务必遵守本说明书中所记载的使用条件、环境以及所装不间断电源(UPS)的使 用条件、环境。 请取出电池后将其放置于婴幼儿无法触及的场所加以保管。...
  • Page 20 即使是因使用本公司产品而发生的事故,本公司对于包括装置·连接设备·软件异常、故障所造成的 损失及其他次生损失的所有损失赔偿概不负责。 ■使用注意事项 将本产品进行废物处理时,请务必按各地方政府规定的排放方式进行处理。 ● Please check our homepage (http://Industrial.omron.eu/, http://www.fa.omron.com.cn) for the newest product information. Each company name and each company product name are the trademarks or registered trademarks of each company. Carrying out unapproved reproduction of a part or all of the contents of this operation manual is forbidden.