Specifications - Omron CQM1H series Operation Manual

Hide thumbs Also See for CQM1H series:
Table of Contents

Advertisement

Specifications

2-2

Specifications

General Specifications
Performance Specifications
Item
Sensor type (See previous page for
temperature ranges.)
Number of control loops
Control output
Control mode
Setting and display accuracy
Hysteresis adjustment
Proportional band
Derivative time
Integral time
Manual manipulated variable
Control period
Input shift value
Sampling period
Output refresh period
Current consumption
Weight
Dimensions
The general specifications of the CQM1-TC20j/TC30j conform to those of the
CQM1H/CQM1 Series.
Units for thermocouples
(CQM1-TC20j)
K, J, T, L, R, S, B
2 loops or 4 loops (2-loop model has heater burnout alarm)
NPN or PNP output with short-circuit protection
Power supply voltage: 24 VDC
Maximum switching capacity: 100 mA per output
Leakage current: 0.1 mA max.
Residual voltage: 0.8 V max.
ON/OFF control, advanced PID control (2 degrees of freedom), or manual
operation
°C Ranges
(Process value ±0.3% or ±1 °C,
whichever is larger) ±1 digit max.
°F Ranges
(Process value ±0.3% or ±2 °F,
whichever is larger) ±1 digit max. (See
note 1.)
The accuracy is given when the cold
junction compensator on the terminal
block is used. Always use the cold
junction compensator on the terminal
block. (See note 2.)
0.1 to 999.9 °C/°F (0.1°C/°F unit)
0.1 to 999.9 °C/°F (0.1°C/°F unit)
0 to 3,999 s (1 s unit)
0 to 3,999 s (1 s unit)
0.0 to 100.0% (0.1% unit)
1 to 99 s (1 s unit)
–99.9 to 999.9 °C/°F (0.1°C/°F unit)
0.5 s
0.5 s
190 mA max. at 5 VDC
200 g max.
32 x 110 x 107 mm (W x H x D)
1. The accuracy of K and J thermocouples at or below –100 °C is ±2 °C ±1 digit
Note
max., and the accuracy of R and S thermocouples at or below 200 °C is ±3
°C ±1 digit max. The accuracy of B thermocouples at or below 400 °C is not
specified.
2. When returning a Unit for repairs, always include the terminal block (or the
cold junction compensator).
Specification
Units for platinum resistance
thermometers (CQM1-TC30j)
Pt100, JPt100
+10%
/
–15%
0.1 °C Ranges
(Process value ±0.3% or ±0.8 °C,
whichever is larger) ±1 digit max.
0.1 °F Ranges
(Process value ±0.3% or ±1.6 °F,
whichever is larger) ±1 digit max. (See
note 1.)
0.01 °C Ranges
(Process value ±0.3% or ±0.5 °C,
whichever is larger) ±1 digit max.
0.1 °C Ranges
–99.9 to 999.9 °C/°F (0.1°C/°F unit)
0.01 °C Ranges
–9.99 to 99.99 °C/°F (0.01°C/°F unit)
Section 2-2
235