Omron CQM1H series Operation Manual page 151

Hide thumbs Also See for CQM1H series:
Table of Contents

Advertisement

Nomenclature
Indicators
Features
Sensor Unit
Remote Console
Name
Color
OPERATION
Orange
STABILITY
Green
TEACHING
Red/Green
• The module selected is set to the operation monitor mode or teaching mode
using the mode setting selector of the CQM1-TU001.
• When the CQM1-TU001 is in operation monitor mode, the operation of the
module selected with the module selector of the CQM1-TU001 can be moni-
tored with the operation indicator and stability operation indicator of the
CQM1-TU001.
• When the module selector is set to the 0, module 0 will be selected. Slide the
module selector and set to 1 for module 1, 2 for module 2, and 3 for module 3.
• Set the mode setting selector to SET before setting the Sensor Unit to the
teaching mode and set the mode setting selector to RUN before setting the
Sensor Unit to the operation monitor mode.
The READY indicator (green) is lit when the I/O bus of the CQM1-SEN01 is
ready to retrieve signals after the CQM1-SEN01's address is set properly with
the CPU. The output indicators (orange) are lit according to the operation of
each module inserted to slots 0 to 3 of the CQM1-SEN01.
• The stability operation indicator (green) and operation indicator (orange) of the
CQM1-TU001 correspond to the stability operation indicator (green) and op-
eration indicator (orange) of each sensor module.
• The teaching indicator (red/green) on the CQM1-TU001 is used as a teaching
monitor for the module selected.
• The operation indicator is lit when a sensing object is within the sensing dis-
tance and the object will be detected. The stability operation indicator shows
the stability of detecting or non-detecting operations. The stability operation
indicator will be lit when a sensing object is located 0.93 times as near as the
sensing distance or less. The stability operation indicator will be also lit when a
sensing object is located 1.07 times as far as the sensing distance or more.
Operation indica-
tor (orange)
Stable
non-
OFF
sensing zone
Stable sens-
ON
ing zone
Function
Lit when the control output of the sensor module
specified with the module selector is ON.
Lit when the operation of the sensor module
specified with the module selector is stable.
Indicates the teaching status of sensitivity setting.
Stability operation
indicator
ON
Setting distance
OFF
Setting distance
Setting distance
ON
Section 2-1
x
approx. 1.07
x
approx. 0.93
131

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cqm1 series

Table of Contents