H3C S3600 Series Installation Manual page 97

Hide thumbs Also See for S3600 Series:
Table of Contents

Advertisement

Installation Manual
H3C S3600 Series Ethernet Switches
Multimeter
Tilted wire cutter
II. Installation procedure
Step 1: Tear the protection paper at one side of the double faced adhesive tape apart
from the tape, and stick the tape on the surface of the arrester. Tear the protection
paper at another side apart from the tape, and stick the arrester onto the chassis of the
switch. The arrester should be attached on the chassis as close to the grounding screw
as possible.
Step 2: According to the distance to the grounding screw of the switch, cut the ground
wire of the arrester, and securely tightening its ground wire to the grounding screw of
the switch.
Step 3: Use the multimeter to measure whether the ground wire of the arrester contacts
well with the grounding screw of chassis.
Step 4: According to the instruction of arrester for network port, connect the arrester
with switch by the cables (be carefully with the cable direction. Outdoor network cable
should be inserted into the arrester's IN end, and the cable connected to the switch
should be inserted into the arrester's OUT end). When you do that, observe whether
the arrester indicators normally display.
Note:
The instruction of lightning arrester for network port contains the technical
specifications, installation and maintenance guide of the arrester. Please carefully read
it before installing the arrester.
Step 5: Use the nylon ties to bundle the cables neatly.
Power input
Figure A-2 Installation diagram of lightning arrester for network po
Network cable indoors
Switch
A-3
Appendix A Lightning Protection of the Switch
Network cab
le led into from outdoor
Lightning arre
ster for network port
(attached ont
o the chassis)
Ground wire o
f lightning arrester
Grounding s
crew of switch
Metal cab
inet that contains the switch
rt

Advertisement