Recovering The Boot Rom Password - H3C S3600 Series Installation Manual

Hide thumbs Also See for S3600 Series:
Table of Contents

Advertisement

Installation Manual
H3C S3600 Series Ethernet Switches
Select <7> and restart the switch. After that, the system will skip the configuration file.

6.2.2 Recovering the Boot ROM Password

Contact your sales agent for help.
6.3 Dealing with Power System Failures
You can know whether the power system has failed by reading the PWR LED on the
front panel. If the power system is operating normally, the PWR LED is ON. If not, check
that:
The switch power cord is correctly connected.
The power source can work with the switch.
6.4 Dealing with Configuration System Failures
If the switch is operating normally after it is powered up, it displays the start-up
information on the console terminal. If the configuration system has failed, it displays
illegible characters or nothing at all.
I. No information on the terminal
Take these steps to address the problem:
1)
Check that:
The power system is operating normally.
The console cable is connected correctly.
2)
Check that the console cable is in good condition and the terminal (HyperTerminal
for example) parameter settings are correct.
II. Illegible characters on the terminal
Make sure you have set on your terminal (HyperTerminal):
Bits per second: 9600
Data bit: 8
Parity check: none
Stop bit: 1
Flow control: none
Terminal emulation: VT100
Reconfigure the parameters if their values are different.
Chapter 6 Maintenance and Troubleshooting
6-2

Advertisement

Table of Contents
loading

Table of Contents