Blade Load Factors - NEC UX5000 Hardware Manual

Hide thumbs Also See for UX5000:
Table of Contents

Advertisement

S
2-3
ECTION

Blade Load Factors

In addition to the blade capacities listed on the previous pages, you must take into consideration the power
load factors for certain blades as well as station equipment (such as telephones, telephone adapters, and
consoles).
The maximum load factor for blades per system chassis (either 9.5" Chassis-B/E or 19" Chassis-A) is 7. The
maximum load factor for station equipment is either 64 (for 9.5" Chassis-B/E) or 80 (for 19: Chassis-A).
Refer to the following charts to determine the load factor for your equipment. Any blades or devices not
listed in these charts do not require consideration when determining the load factor. Keep in mind that each
19" chassis (either 2 9.5" chassis combined or 1 19" chassis) has a maximum number of timeslots for audio
of 104. This means that any blade combination within one system chassis cannot exceed 104 station or
trunk ports.
Make additional copies of these pages for each chassis to be configured.
Each Blade
CCPU
RTU
APSU
GSW
PVA
32VOIPDB
64VOIPDB
128VOIPDB
The total number cannot exceed 7 for a 9.5" Chassis-B/E or 19" Chassis-A.
The Station Equipment Load Factor must also be considered.
Chapter 2
Blade Load Factor Table
Load Factor
1
2
2
2
1
1
2
2
Chapter 2 - Blade Installation and Startup
Number Installed
Total
2 - 13

Advertisement

Table of Contents
loading

Table of Contents