Chapter 2 - Blade Installation and Startup
For more information on Cold and Hot system starts, refer to
(CCPU) Blade (Figure 2-4 - Figure 2-5)
2.9.2

Initial Installation of Trunk Blades

When first installing the system:
1.
Insert all blades in sequential order. The installer must install trunk blades in order (i.e.; slot 5 first, slot 6
next, slot 7 next, etc.) for a sequential numbering plan.
Installing COIU, 4TLIU, DIOPU, or BRI Blade's:
The order in which trunk blades are physically inserted determines the numbering plan.
For example, if four blades are installed in the following order, the numbering plan below
would apply:
Installing T1/PRI Blades
The T1/PRI Interface blade uses the first block of 24 consecutive trunks.
For example, if you have an 4COIU blade with a 4COIDB installed for trunks 1-8, the T1/
PRI blade will automatically use trunks 9-32. If you have 4COIU blade with a 4COIDB
installed for trunks 1-8 and 17-24, the T1/PRI blade will use trunks 25-48. The T1/PRI
blade cannot use trunks 9-16 (even if available) since they are not part of a consecutive
block of 24 trunks.
2.9.3

Initial Programming

The system can be programmed using three methods:
Programming through a digital or IP keyset
PC Programming
Web Programming
Refer to the UX5000 Software Manual (P/N 0913200) for complete details on programming.
2 - 86
Order of
Blade Slot #
Install
1
5
2
6
3
8
4
7
UX5000 Central Processing Unit
(page 2-15).
Blade
Line Circuits
4COIU with
4COIDB
4COIU
4TLIU
4TLIU
1-8
9-12
13-16
17-20