Chapter 2 - Blade Installation and Startup
2.7.5
BRI (2BRIU) Interface Blade (Figure 2-34)
The BRI blade provides:
●
2 (2BRIU) 2-Channel Circuits (2B + D) configured as T-Bus or S-Bus
●
64 Kb/s Clear B-Channel and 16 Kb/s D-Channel
●
2 blade status LEDs
●
Connector for 2BRIDB
These trunk circuits can be connected to either ISDN trunks or ISDN telephones, depending on the switch
setting within system programming. All ISDN telephone circuits (#1-2 and #3-4 [with the BRI daughter board])
are supplied DC power from the UX5000 system.
When used for S-Bus, a maximum of 8 ISDN terminals can be connected to each circuit.
The BRI Interface blade uses a single universal slot. Each blade connects to the network via an NTI Network
Termination.
In order to block new calls on the blade, system programming (Program 90-05-01, Menu 3) must be used. This
program will prevent new calls from being established on the blade, but it will not terminate any existing calls.
2 - 70
ISDN Terminal
Interface
Busy LED
Staus LED
Figure 2-34:
BRI BLADE - COMPONENT SIDE
Chapter 2