2.7.5

BRI (2BRIU) Interface Blade (Figure 2-34)

The BRI blade provides:
2 (2BRIU) 2-Channel Circuits (2B + D) configured as T-Bus or S-Bus
64 Kb/s Clear B-Channel and 16 Kb/s D-Channel
2 blade status LEDs
Connector for 2BRIDB
These trunk circuits can be connected to either ISDN trunks or ISDN telephones, depending on the switch
setting within system programming. All ISDN telephone circuits (#1-2 and #3-4 [with the BRI daughter board])
are supplied DC power from the UX5000 system.
When used for S-Bus, a maximum of 8 ISDN terminals can be connected to each circuit.
The BRI Interface blade uses a single universal slot. Each blade connects to the network via an NTI Network
Termination.
In order to block new calls on the blade, system programming (Program 90-05-01, Menu 3) must be used. This
program will prevent new calls from being established on the blade, but it will not terminate any existing calls.
2 - 70
ISDN Terminal