NEC UX5000 Hardware Manual page 291

Hide thumbs Also See for UX5000:
Table of Contents

Advertisement

Device
Key Telephone,
DSS Console:
Single Line
Telephone, Analog
Terminals:
SLT Adapter:
SLTAD to SLT:
PSA Adapter:
2PGDAD Adapter:
Using Under Carpet Cable:
Use stranded wire under carpet cable. The use of this cable decreases the cable run length by 50%.
CCPU to PC:
NTCPU to Hub:
Chapter 6
UX5000 Cable Requirements
Cable Type
CAT5
2-wire 26 AWG
2-wire 24 AWG
2-wire 22 AWG
CAT5
2-wire 26 AWG
2-wire 24 AWG
2-wire 22 AWG
CAT5
2-wire 26 AWG
2-wire 24 AWG
2-wire 22 AWG
2-wire 26 AWG
CAT5
2-wire
CAT5
2-wire 26 AWG
2-wire 24 AWG
2-wire 22 AWG
LAN
4-wire
UTP
10Base-T/
100Base-
TX
LAN
10Base-T: 4--wire
UTP
100Base-TX: 8-wire
10Base-T/
100Base-
TX
Chapter 6 - Specifications and Parts List
Cable Run Length (ft)
1312
2790
(no AC or options)
3940
(with AC, no options)
2624
3280
4921
8202
1148
1968
2624
2953
Loop Resistance:
Below 1700 Ohm
1312
1968
2624
328
328
Notes
Constant Current: 20mA
Loop Resistance: Below
600 Ohm (Includes
resistance of telephone)
500 Ohms resistance
between SLT adaptor and
terminal (including phone's
DC termination)
Internal resistance of PSA:
350 Ohms (20mA)
(includes resistance of
PSA)
6 - 29