10. Alternator/Starting Clutch
Remove the flywheel with the flywheel puller.
Special service tools:
Flywheel puller
shaft protector
Caution
Install a shaft protector on the right end of
crankshaft to avoid damaging the crankshaft
before installing the flywheel puller.

Alternator Coil Set Removal

Remove the couplers of the alternator and pulse
generator.
Remove the 6 bolts for the pulse generator, the
alternator coil and cable guide. Then, remove
the alternator assembly.
Caution
Do not damage the alternator coil.

Right Crankcase Cover Removal

Remove the right crankcase cover. (8 bolts)
Remove setting pin and gasket.
Remove the gasket or foreign materials on the
connection surfaces of both the cover and
crankcase.
Caution
Do not damage the connection surfaces.
10-4
This Chapter Contents
Alternator coupler
Cable guide
Coil
Flywheel puller
Pulse generator
coupler
Pulse
generator
8 bolts