3.1 Installation requirements

Environmental conditions
The table below summarizes the physical environment in which the XDX series projector can be operated or
stored.
Environment
Ambient Temperature
Air cleanliness
Humidity
Altitude
Let the projector acclimatize after unpacking. Neglecting this may result in a failure in the start-up of
the Light Processor Unit.
Use in high altitude conditions
Combining high altitude and high ambient temperature creates extra challenging conditions for any electronics
system; projectors are no exception to this. The system can be used up to 4.000 m (13.125 ft) altitude
maximum ambient temperature should be reduced once exceeding 2.500 m (8.202 ft). This in accordance
with the following table:
Altitude (m)
0
2 000
2 500
3 000
3 500
4 000
Main Power requirements
Depending on the available power circuit, all XDX projectors can operate from a single-phase power net or
three-phase power net.
Power system
three-phase power net
single-phase power net
The projector must be switched internally between a star connection (Y), a delta connection (Δ) or a mono-
phase connection or vice versa. See
The power cord required to connect the projector with the power net is not delivered with the projector. It is the
responsibility of the customer to provide the correct type of power cord. The cross-sectional area of the
conductors in the power supply cord shall not be less than 4 mm
In single-phase operation, the power cord must be rated for minimum 300 V.
1.
Limited to 2.000 meters (6.562 feet) for Chinese Mainland due to local regulations.
28
R5914481 /00
XDX
Operating
10°C (50°F) to 40°C (104°F)
Clean office environment (equivalent with
clean room standard ISO 14644-1 ISO Class
9)
5% RH to 85% RH Non-Condensed
-60 (-197 ft) to 4.000 m (13.125 ft)
Altitude (ft)
0
6 562
8 202
9 842
11 483
13 123
Power requirements
200–240V/346–415V, 3W+N+PE, 15A, 50/60 Hz (Y)
200–240V, 3W+PE, 20A, 50/60 Hz (Δ)
200–240 VAC, L1+L2/N+PE, 25A, 50/60 Hz
"Connecting the projector with the power net", page
Non-Operating
-15°C (5°F) to 60°C (140°F)
n.a.
5% to 95% RH Non-Condensed
1
-60 (-197 ft) to 10.000 m (32.810
ft)
Temp (°C)
40
40
39
38
37
35
2
(10 AWG).
1
, but the
Temp (°F)
104
104
102
100
99
97
45.