Setting Test Equipment; Starting Adjustment Program (Zmap) - Hitachi VK-U174 Service Manual

Color video camera
Table of Contents

Advertisement

Adjustment > Preparations for Adjustment

6-1-4 Setting test equipment

(1) Oscilloscope
The names of switches, knobs, modes, etc. of oscilloscope may vary slightly depending on the
manufacturer or model. Since some oscilloscopes may have switches, etc. other than the above that
must be set, see the instruction manual of the particular oscilloscope for details.
1) Probe:
2) TIME/DIV:
3) VOLTS/DIV:
4) Synchronization:
5) AC/DC/GND:
(2) Vectorscope
1) SATURATION:

6-1-5 Starting adjustment program (ZMAP)

1) Connect the video camera, DSP-R jig and PC as shown in
Fig. 2-1, and supply power to them. If the connection of
jig, etc. is inappropriate or power is not supplied, the
adjustment program will not start normally.
2) Operate the PC to start MS-DOS. For details on how to
start MS-DOS, refer to the instruction manual of PC,
since this varies for each PC.
3) Make sure that the adjustment floppy disk is write-
protected.
4) Insert the adjustment floppy disk into the floppy disk
drive of PC.
5) Use the PC keyboard to type A: and press Enter key.
(See the MS-DOS screen-1 and 2)
The letter to be input is to designate the drive into which
the adjustment floppy disk has been inserted. If using a
drive other than A, designate the drive.
6) Input ZMAP2003 (space) 1 and press Enter key. (See the
ZMAP input screen)
The number to be input after a space is to designate the
serial port no. of PC. If the PC has two or more serial
ports, and the DSP-R jig is connected to a port other
than serial port 1, input the serial port number.
10:1
10 or 20 µs (except for a case where some designation is given)
Will vary depending on the measurement object (except for a case where
some designation is given)
Internal sync (except for a case where some designation is given)
AC (except for a case where some designation is given)
75%
MS-DOS screen-1
C>
Input A and press
Enter key.
MS-DOS screen-2
C>A:
A>
Input ZMAP
2003 (space) 1.
ZMAP input screen
C>A:
A>ZMAP2003 1
Press Enter key.
6 - 3
(Continued on next page)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vk-u174e

Table of Contents