Item No.
U199
Displaying fuser heater temperature
Description
Displays the detected fuser temperature.
Purpose
To check the fuser temperature.
Method
1. Press the start key. The fuser temperature is displayed.
Completion
Press the stop key. The screen for selecting a maintenance mode No. is displayed.
U201
Initializing the touch panel
Description
Automatically correct the positions of the X- and Y-axes of the touch panel.
Purpose
To automatically correct the display positions on the touch panel after it is replaced.
Method
1. Press the start key.
2. Select the [Initialize] or [Check].
Initialize
Check
Method: [Initialize]
1. Press the start key.
2. Press the center of the + keys. Be sure to press three + keys displayed in order.
The touch panel is adjusted automatically.
3. Press the indicated three + keys, and then check the display.
4. Press the stop key. The screen for selecting a maintenance item No. is displayed.
Method: [Check]
1. Press the start key.
2. Press the indicated three + keys, and then check the display.
When adjusting the display, press [Initialize] to execute the adjustment automatically.
3. Press the stop key. The screen for selecting a maintenance item No. is displayed.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Display
Adjusts the display on the panel automatically
Checks the display on the touch panel
Description
Description
1-3-43
2K3/2L3