Kyocera FS-6025MFP/B Service Manual page 74

Hide thumbs Also See for FS-6025MFP/B:
Table of Contents

Advertisement

Item No.
U099
Adjusting original size detection
Description
Checks the operation of the original size sensor and sets the sensing threshold value.
Purpose
To adjust the sensitiveness of the sensor and size judgement time if the original size sensor mal-
functions frequently due to incident light or the like.
Method
1. Press the start key.
2. Select the item. The screen for executing each item is displayed.
Data1
B/W Level1
Data2
Method: [Data1/Data2]
1. Place the original and close the original cover or DP. The detection sensor transmission data
is displayed.
Original Area R
Original Area G
Original Area B
Original Area
Size SW L
Display
Displaying original size sensor transmission data
B/W LEVEL setting original size sensor threshold value
Setting original size judgment time
Displaying original size sensor transmission data
(when DP is installed)
Display
Detected original width size (R)
Detected original width size (G)
Detected original width size (B)
Detected original width size
Displays the original size sensor (OSS) ON/OFF
Description
Description
Description
1-3-36
2K3/2L3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Taskalfa 305Fs-6030mfpTaskalfa 255/b