Connector
Pin
YC1
1
FG
Connected to
2
ENG_TMG
engine PWB
3
ENG_RDY
4
ENG_SEL
5
ENG_CLK
6
ENG_SI
7
ENG_SO
8
ENG_OPEN
9
NC
10
GND
11
GND
12
GND
13
NC
14
+24V
15
+24V
16
+24V
YC2
1
ANODE
Connected to
2
GND
DP original
3
LS_SW
size length
sensor
YC3
1
ANODE
Connected to
2
GND
DP original
3
SET_SW
sensor
YC4
1
WID1
Connected to
2
GND
DP original
3
WID2
size width
4
WID3
sensor
Signal
I/O
-
-
O
0/3.3 V DC
O
0/3.3 V DC
I
0/3.3 V DC
I
0/3.3 V DC(pulse)
I
0/3.3 V DC(pulse)
O
0/3.3 V DC(pulse)
O
0/3.3 V DC
-
-
-
-
-
-
-
-
-
-
O
24 V DC
O
24 V DC
O
24 V DC
O
3.3 V DC
-
-
I
0/3.3 V DC
O
3.3 V DC
-
-
I
0/3.3 V DC
I
0/3.3 V DC
-
-
I
0/3.3 V DC
I
0/3.3 V DC
Voltage
Ground
DPTS: On/Off
Ready signal
Select signal
Clock signal
Serial communication data signal
Serial communication data signal
DPOCS: On/Off
Not used
Ground
Ground
Ground
Not used
24 V DC power input from EPWB
24 V DC power input from EPWB
24 V DC power input from EPWB
3.3 V DC power output to DPOLS
Ground
DPOLS: On/Off
3.3 V DC power output to DPOS
Ground
DPOS: On/Off
DPOWS: On/Off
Ground
DPOWS: On/Off
DPOWS: On/Off
2-3-25
2K3/2L3
Description