8. ALARM INPUT LINK:
Enter and set each channel to activate ( ON ) or deactivate ( OFF ) the three modes of "SENSOR",
"V ( VIDEO )-LOSS", and "ACTIVE".
SENSOR: An alarm is triggered when the sensor is touched.
V-LOSS: An alarm occurs when video is lost.
ACTIVE: Alarms which are activated while the motion detection function is operating.
9. ALARM OUT LINK:
Enter and activate ( YES ) or deactivate ( NO ) the three alarm output modes of "SENSOR",
"V-LOSS" and "ACTIVE" for the following : ALARM OUT 1, 2, and 3, BUZZER, START
RECORDING, and the DISPLAY and CALL UP functions of the MAIN/CALL monitors.
10. RETURN
Go back to the previous page.

5.6.2 RECORD SETTING

This page enables you to set the recording rate and recording quality, and enables you to set the audio
sampling rate and the channel mode.
ADVANCED SETTING
1 ALARM SETTING:
2 RECORD SETTING:
3 MOTION SETTING:
4 CAMERA COVER:
5 OPERATION LOCK:
6 COMMUNICATION:
7 DISK SETUP:
8 SCHEDULE:
RETURN
menu: exit
enter: select
▲ /▼ /jog/ch1~8: item
1. RECORD QUALITY:
You can enter and set each channel's record quality at 4 different levels of recording images from
"BEST","HIGH", and "STANDARD" to "BASIC".
2. NORMAL RECORD RATE:
The rate range is from 1 field per second (F/S) to 60 F/S.
3. AUDIO SAMPLING RATE:
This item has 4 options: "44K Hz", "22K Hz", "8K Hz", and "DISABLE".
4. AUDIO CHANNEL MODE
The options here are "STEREO" ( two channels with the same input ), and "LEFT INPUT" and
"RIGHT INPUT" ( two channels which work separately ).
RECORD SETTING
ENTER
1 RECORD QUALITY:
ENTER
2 NORMAL RECORD RATE:
ENTER
3 AUDIO SAMPLING RATE:
ENTER
4 AUDIO CHANNEL MODE:
ENTER
RETURN
ENTER
ENTER
ENTER
menu: exit
enter: select
shuttle: value
▲ /▼ /jog/ch1~4: item
46
ENTER
30 F/S
44K Hz
STEREO