Item No.
U425
Setting the target
Description
Enters the lab values that is indicated on the back of the chart (P/N: 302FZ56990) used for
adjustment.
Purpose
Performs data input in order to correct for differences in originals during automatic adjustment.
Method
1. Press the start key.
2. Select the item to be set using the cursor up/down keys.
Display
N875
N475
N125
CYAN
MAGENTA
YELLOW
RED
GREEN
BLUE
ADJUST ORIGINAL
3. Select the item to be set using the cursor up/down keys.
Display
L
a
b
4. Enters the value that is indicated on the back of the chart using the cursor left/right keys or
numeric keys.
5. Press the start key. The value is set.
Description
Description
Setting the N875 patch for the original for adjustment
Setting the N475 patch for the original for adjustment
Setting the N125 patch for the original for adjustment
Setting the cyan patch for the original for adjustment
Setting the magenta patch for the original for adjustment
Setting the yellow patch for the original for adjustment
Setting the red patch for the original for adjustment
Setting the green patch for the original for adjustment
Setting the blue patch for the original for adjustment
Setting the main and auxiliary scanning directions
Description
Setting the L value
Setting the a value
Setting the b value
1-3-20
2MH/2MJ/2MK/2ML
Setting range
0.0 to 100.0
-200.0 to 200.0
-200.0 to 200.0