Code
3200
Exposure lamp error
The exposure lamp is not turned on.
3300
AGC error
After AGC, correct input is not
obtained at CCD.
Contents
Causes
Defective FFC
Reinsert the FFC. Also check for conti-
between scan-
nuity within the FFC. If none, remedy or
ner PWB
replace the FFC.
(YC103) and
control PWB
(YC6), or
improper FFC
insertion.
Defective FFC
Replace the image scanner unit (ISU)
between CCD
(See page 1-5-21).
PWB (YC1) and
control PWB
(YC8).
Defective har-
Reinsert the connector. Also check for
ness between
continuity within the connector har-
CCD PWB (YC3)
ness. If none, remedy or replace the
and LED drive
harness.
PWB (YC1), or
improper con-
nector insertion.
Defective har-
Reinsert the connector. Also check for
ness between
continuity within the connector har-
LED drive PWB
ness. If none, remedy or replace the
(YC2) and expo-
harness.
sure lamp, or
improper con-
nector insertion.
Defective expo-
Replace the exposure lamp (See page
sure lamp.
1-5-27).
Defective LED
Replace the LED drive PWB (See page
drive PWB.
1-5-27).
Defective control
Replace the control PWB (See page 1-
PWB.
5-37).
Defective FFC
Replace the image scanner unit (ISU)
between CCD
(See page 1-5-21).
PWB (YC1) and
control PWB
(YC8).
Defective expo-
Replace the exposure lamp (See page
sure lamp.
1-5-27).
Defective CCD
Replace the CCD PWB.
PWB.
Defective control
Replace the control PWB (See page 1-
PWB.
5-37).
1-4-12
2MH/2MJ/2MK/2ML
Remarks
Check procedures
/corrective measures