U010Xx Error Code Table: G3 Transmission - Kyocera FS-1030MPF Service Manual

Hide thumbs Also See for FS-1030MPF:
Table of Contents

Advertisement

(2-5) U010XX error code table: G3 transmission

Error code
An FTT signal was received for a set number of times after TCF signal transmission at
U01000
2400 bps. Or, an RTN signal was received in response to a Q signal (excluding EOP)
after transmission at 2400 bps.
Function of the unit differs from that indicated by a DIS signal.
U01001
No relevant signal was received after transmission of a DNL (MPS or EOM) signal, and
U01010
the preset number of command retransfers was exceeded (between units of our make).
No relevant signal was received after transmission of a DCS, TCF signal, and the preset
U01011
number of command retransfers was exceeded.
No relevant signal was received after transmission of an NSS1, NSS2 (TCF) signal, and
U01012
the preset number of command retransfers was exceeded (between units of our make).
No relevant signal was received after transmission of an NSS3, TCF signal, and the pre-
U01013
set number of command retransfers was exceeded (between units of our make).
No relevant signal was received after transmission of an MPS signal, and the preset
U01014
number of command retransfers was exceeded.
No relevant signal was received after transmission of an EOM signal, and the preset
U01015
number of command retransfers was exceeded.
An MCF signal was received but no DIS signal was received after transmission of an
U01016
EOM signal, and T1 timeout was detected.
No relevant signal was received after transmission of an EOP signal, and the preset
U01017
number of command retransfers was exceeded.
No relevant signal was received after transmission of a PRI-EOP signal, and the preset
U01018
number of command retransfers was exceeded.
No relevant signal was received after transmission of a CNC signal, and the preset num-
U01019
ber of command retransfers was exceeded (between units of our make).
No relevant signal was received after transmission of a CTC signal, and the preset num-
U01020
ber of command retransfers was exceeded (ECM).
No relevant signal was received after transmission of an EOR.Q signal, and the preset
U01021
number of command retransfers was exceeded (ECM).
No relevant signal was received after transmission of an RR signal, and the preset num-
U01022
ber of command retransfers was exceeded (ECM).
No relevant signal was received after transmission of a PSS.NULL signal, and the preset
U01023
number of command retransfers was exceeded (ECM).
No relevant signal was received after transmission of a PSS.MPS signal, and the preset
U01024
number of command retransfers was exceeded (ECM).
No relevant signal was received after transmission of a PPS.EOM signal, and the preset
U01025
number of command retransfers was exceeded (ECM).
No relevant signal was received after transmission of a PPS.EOP signal, and the preset
U01026
number of command retransfers was exceeded (ECM).
No relevant signal was received after transmission of a PPS.PRI-EOP signal, and the
U01027
preset number of command retransfers was exceeded (ECM).
T5 time-out was detected during ECM transmission (ECM).
U01028
Description
1-4-39
2MH/2MJ/2MK/2ML

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fs-1030mfp/dpFs-1130mfpFs-1035mfp/dpFs-1135mfp