(2) Table of general classification

Error code
No response or busy after the set number of redials.
U00000
Transmission was interrupted by a press of the stop/clear key.
U00100
Reception was interrupted by a press of the stop/clear key.
U00200
Recording paper on the destination unit has run out during transmission.
U00300
A connection was made but interrupted during handshake with the receiver unit (See
U004XX
page 1-4-37 ).
Multiple communication was interrupted and call was not made on destination units after
U00500
interruption.
Communication was interrupted because of a machine problem (See page 1-4-38 ).
U006XX
Communication was interrupted because of a problem in the destination unit.
U00700
A page transmission error occurred in G3 mode (See page 1-4-38 ).
U008XX
A page reception error occurred in G3 mode (See page 1-4-38 ).
U009XX
Transmission in G3 mode was interrupted by a signal error (See page 1-4-39 ).
U010XX
Reception in G3 mode was interrupted by a signal error (See page 1-4-41 ).
U011XX
An invalid one-touch key was specified during communication.
U01400
A communication error occurred when calling in V.8 mode.
U01500
A communication error occurred when called in V.8 mode.
U01600
A communication error occurred before starting T.30 protocol during transmission in V.34
U017XX
mode (See page 1-4-42 ).
A communication error occurred before starting T.30 protocol during reception in V.34
U018XX
mode (See page 1-4-43 ).
Relay broadcast was refused by a relay station because of a mismatch in permit ID num-
U02000
ber and permit telephone number when a relay command was issued.
A relay command failed because the destination unit (relay station) had no relay broad-
U02100
cast capability.
A relay command from a command station failed because a telephone number that was
U02200
not registered in the relay station was specified. Or, relay broadcast was requested to a
relay station but failed because a telephone number that was not registered in the relay
station was specified. Or, Subaddress-based relay broadcast transmission failed
because the data registered in the Subaddress relay box was deleted.
Receiving station information was not normally received in reception of a relay command
U023XX
(See page 1-4-43 ).
An interoffice subaddress-based relay transmission was interrupted because of a mis-
U02400
match in the specified relay box number.
No document was present in the destination unit when polling reception started.
U03000
In reverse polling, although no original was set in the destination unit, transmission was
U03100
complete.
In confidential polling reception, data was not accumulated in the specified box in the
U03200
destination unit. Or, in interoffice subaddress-based bulletin board reception, data was
not stored in the box specified by the destination unit.