Kyocera FS-1030MPF Service Manual page 133

Hide thumbs Also See for FS-1030MPF:
Table of Contents

Advertisement

Error code
Relay broadcast was requested from a command station but memory overflowed during
U12000
reception. Or, in subaddress-based relay reception, memory overflowed.
Relay was commanded but memory overflowed in the destination unit (relay station).
U12100
Memory overflowed during confidential reception. Or, in subaddress-based confidential
U14000
reception, memory overflowed.
Memory overflowed in the destination unit during confidential transmission. Or, in interof-
U14100
fice subaddress-based transmission, memory overflowed in the destination unit.
Memory overflowed during memory reception.
U19000
Memory overflowed in the destination unit during transmission.
U19100
Memory transmission failed because a decoding error occurred.
U19200
Transmission failed because an error occurred during JBIG encoding.
U19300
Reception failed because an error occurred during JBIG decoding.
U19400
Description
1-4-36
2MH/2MJ/2MK/2ML