Kyocera FS-1030MPF Service Manual page 132

Hide thumbs Also See for FS-1030MPF:
Table of Contents

Advertisement

Error code
In polling reception from a unit of our make, operation was interrupted due to a mismatch
U03300
in permit ID or telephone number. Or, in interoffice subaddress-based bulletin board
reception, operation was interrupted due to a mismatch in permit ID or telephone num-
ber.
Polling reception was interrupted because of a mismatch in individual numbers (destina-
U03400
tion unit is either of our make or by another manufacturer).
In confidential polling reception, the specified confidential box No. was not registered in
U03500
the destination. Or, in interoffice subaddress-based bulletin board reception, the speci-
fied Subaddress confidential box number was not registered in the destination unit. Or,
the destination was being accessed.
Confidential polling reception was interrupted because of a mismatch in specified confi-
U03600
dential box No. Or, an interoffice subaddress-based bulletin board reception was inter-
rupted because of a mismatch in the specified subaddress confidential box number.
Confidential polling reception failed because the destination unit had no confidential poll-
U03700
ing transmission capability or data was not accumulated in any box in the destination
unit. Or, interoffice subaddress-based bulletin board reception failed because the desti-
nation unit had no subaddress-based bulletin board transmission capability, or data was
not stored in any subaddress confidential box in the destination unit.
The confidential box specified for confidential transmission was not registered in the des-
U04000
tination unit. Or, in interoffice subaddress-based transmission mode, the specified sub-
address box number was not registered in the destination unit. Or, the destination was
being accessed.
Confidential transmission failed because the destination unit had no confidential capabil-
U04100
ity. Or, subaddress-based transmission failed because the destination unit had no sub-
address-based reception capability.
In encrypted transmission, the specified encryption box was not registered in the desti-
U04200
nation unit.
Encrypted transmission failed because the destination unit had no encrypted communi-
U04300
cation capability.
Communication was interrupted because of an encryption key error during encrypted
U044XX
transmission (See page 1-4-43 ).
Encrypted reception was interrupted because of a mismatch in encryption keys.
U04500
In transmission with a specified number, the set number of originals was different from
U05000
the number of transmitted originals.
Password check transmission or restricted transmission was interrupted because the
U05100
permit ID's did not agree with.
Password check reception or restricted reception was interrupted because the permit
U05200
ID's did not match, the rejected FAX number's did match, or the destination receiver did
not return its phone number.
The password check reception or the restricted reception was interrupted because the
U05300
permitted numbers did not match, the rejected numbers did match, or the machine in
question did not acknowledge its phone number.
G3 communication was attempted but failed because the destination unit was a G2
U09000
machine.