19  Parameter Lists

19.2.2 Battery Settings (220#)

221# Battery Property
No. Name
01
BatTyp
02
BatCpyNom
03
BatVtgNom
04
BatTmpMax
05
BatTmpStr
06
BatWirRes
07
BatFanTmpStr
168
SI4548-6048-US-BE-en-21
Description
Value
Battery type
VRLA
FLA
NiCd
LiIon_Ext-BMS
Nominal battery
100 Ah to
capacity
10,000 Ah
50 Ah to
10,000 Ah
Nominal battery
voltage
Max. battery
104°F to 122°F
temperature
(40°C to 50°C)
Battery start
32°F to 104°F
temperature
(0°C to 40°C)
following stop due
"BatTmpMax"
to overtemperature
Power resistor of
0 mOhm to
the battery
50 mOhm
connection in
mOhm
Starting
temperature for the
"BatFan" function
SMA Solar Technology America LLC
Explanation
Lead-acid battery
with immobilized
electrolyte in gel or
AGM (Absorbent
Glass Mat
Separator)
Valve-regulated
lead–acid battery
with liquid
electrolyte
Nickel-cadmium
battery
Lithium-ion battery
VRLA/FLA/NiCd
LiIon_Ext-BMS
VRLA
FLA
NiCd
Operating Manual
Default
value
VRLA
100 Ah
48 V
48 V
45.6 V
113°F
(45°C)
104°F
(40°C)
104°F
(40°C)